BGS technic 9530 Manual De Instrucciones página 6

Cilindro hidráulico
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WARNING
Please wear safety glasses, helmet and other necessary personal protective equipment when
operating hydraulic equipment.
Use cylinder to lift load should have solid lifting surface for correct support. Please select steel or
wood blocks that are capable of supporting the load.
Please install pressure gauge in the system to monitor the operating pressure. The gauge must
have same pressure rating as the pump and cylinder(s) in the system. The wrong gauge may
cause equipment failure and possible personal injury.
Please carefully inspect the cylinder(s) and coupler(s) before use cylinder(s) or shift coupler(s).
Never connect the cylinder(s) with damaged coupler(s) or damaged port threads. The damaged
coupler(s) or damaged port thread(s) may cause equipment failure and possible personal injury.
To prevent dust or other debris into cylinder body or tube, please shift coupler(s) in a clean place.
Dirt or other debris will damage the cylinder's seals and result in equipment failure and possible
personal injury.
Cylinder must be placed on a flat base, please use cylinder base for added stability.
Before removing or tightening hose(s) or coupler(s), please release hydraulic pressure in system.
Never handle pressurized hoses; escaping oil under high pressure can penetrate the skin,
causing serious injury. Seek medical aid immediately if injured.
Hydraulic cylinders must use special hydraulic oil, please use oil or other approved hydraulic oil.
Before lifting, saddle or other accessories must be fully seated in piston. Failure to ensure saddle
or other accessory is fully seated can result in damage to hydraulic cylinder and/or severe injury.
Before lifting, if using external collar threads, ensure that accessory is completely threaded onto
cylinder. Failure to ensure accessory is completely threaded onto cylinder body can result in
damage to hydraulic cylinder and/or severe injury.
IMPORTANT
Please keep the cylinder clean all the time.
When the cylinder is not in use, please keep the piston rod fully retracts, remove hose and use
rubber cap(s) to recover the coupler. If you use collar threads, please use the thread protector to
recover it.
Please do not drop heavy duty on hose.
Please do not lift and carry hydraulic cylinders by the hose(s) or coupler(s), use the handle or
other safe way.
Please use hydraulic equipment in normal temperature, do not use equipment in temperatures of
65°C (150°F) or higher. Overheating will soften seals and weakens hose materials, resulting in oil
leaking or other equipment failure.
OPERATION
Before use cylinder, please visually check all units, to make sure there are no damage on cylinder(s),
port threads, coupler(s) and hose(s). No oil leaking and shortage of parts.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed