CoolAir
6.3.2
Menu level 1: Set temperature
The unit always starts with a defined value for the room temperature. This
parameter can be configured between 17 and 30 °C:
➤ Start configuration mode (see Chapter "Starting and ending configu-
ration mode" on page 33).
✓ The first digit of the display (fig. 7 on page 5, item 5) shows the menu
level and the second and third show the parameter which can be set.
➤ Press the Operating Mode button (fig. 7 on page 5, item 4) to
change the parameters.
➤ Use the + and – buttons (fig. 7 on page 5, item 6 and 7) to select the
target value (in °C) at which the unit should start operation.
✓ The digits in the display flash until the parameter you entered is
confirmed.
➤ Press the Operating Mode button (fig. 7 on page 5, item 4) to con-
firm your entry.
✓ The set value is saved and is then used when the unit is restarted.
✓ You are now in menu level 1 again and can use the + and – buttons to
switch between menu levels.
6.3.3
Menu level 2: Low voltage cut-off
The battery monitor protects the battery from excessive discharging.
a
Caution
When the the battery monitor switches the device off, the battery only has
part of its charging capacity. Avoid starting repeatedly or operating elec-
trical consumers. Make sure that the battery is recharged. As soon as the
required voltage is available again, the unit can be operated again.
If only the set power supply is available here for the air conditioning roof
unit, the unit is switched off.
➤ Start configuration mode (see Chapter "Starting and ending configu-
ration mode" on page 33).
✓ The first digit of the display (fig. 7 on page 5, item 5) shows the menu
level and the second and third show the parameter which can be set.
➤ Press the + button (fig. 7 on page 5, 6) once to switch to menu
level 2.
➤ Press the Operating Mode button (fig. 7 on page 5, item 4) to
change the parameter.
✓ The digits in the display flash until the parameter you entered is con-
firmed.