NOTE: For finished deck/rim installations, perform
procedures of this frame. For rough (unfinished) deck
installations, omit procedures in this frame and perform
procedures in frames Fig. #6 thru Fig. #10.
Tighten mounting nuts on each valve body underneath
deck/rim.
Solder copper tubes to valve bodies, tee and spout supply
tube.
Solder hot and cold water tubes to valve body inlets.
Ensure cold supply is on right hand side.
Proceed to Section 3.
NOTE: This frame applicable to rough (unfinished) deck
installations only. (Excludes K-300-KR and K-P300-KR)
Set Valve Body Height: Use one of the following two
formulas to calculate the valve body clearance required
for the finish material at your installation.
If tile to be installed measures less than 1" (2.5cm) thick,
add that measurement to 1-1/4" (3.2cm).
Example #1: Tile thickness 3/4" (2cm) + 1-1/4" (3.2cm) =
2" (5cm) clearance.
If the tile to be installed measures between 1" (2.5cm) and
1-1/4" (3.2cm) thick, add only 1" (2.5cm) to 1-1/4" (3.2cm).
Example #2: Tile thickness 1-1/8" (2.9cm) =1" (2.5cm) +
1-1/4" (3.2cm) = 2-1/4" (5.7cm) clearance.
Adjust threaded collar until the dimension from the top of
the sleeve to the top of the rough deck surface equals the
clearance requirement you calculated.
Note this dimension. You will need to use it again after
connecting the supply tube.
NOTE: Excludes K-300-KR and K-P300-KR, which are
for Finished Deck/Rim Mounts only.
NOTE: This frame applicable to rough (unfinished) deck
installations only. (Excludes K-300-KR and K-P300-KR)
Supply Tube Connection: Measure distance from
bottom of spout supply tube to top of tee.
Add 1" (2.5cm) to this measurement and cut a piece of
1/2" nominal (5/8" O.D.) copper tubing to fit into the supply
tube and tee port.
A
1013511-2-
Hot
Supply
Top Of Sleeve
1-1/4" (3.2cm)
2" (5cm)
À À À À À
Clearance
À À À À À
É É É É É
3/4" (2cm)
É É É É É
2-1/8"
(5.4cm)
Max.
Top Of Sleeve
1-1/4" (3.2cm)
2-1/4" (5.7cm)
À À À À À
Clearance
É É É É É
À À À À À
1-1/8" (2.9cm)
É É É É É
2-1/8"
(5.4cm)
Max.
4
Cold
Supply
Solder
Solder
Solder
Fig. #5
Tile Thickness
Threaded Collar
Rough Deck
EXAMPLE #1
Tile Thickness
Threaded Collar
Rough Deck
EXAMPLE #2
Fig. #6
Spout Supply Tube
Measure
Distance
Tee
Fig. #7