4. DISPLAY
The OLED display switches on automatically when the operating or pressure release but-
tons are pressed, and off after 60 seconds of non-operation.
The display shows:
The main operational parameters of the tool processed by the circuit board, such as
peak pressure or force reached.
Information on the condition of the tool, such as the charge level, the battery tempera-
ture and maintenance requirements.
Any operational or procedural ERRORS.
Use the touch button (8) to navigate through the menu screens to manage INFORMATION
AND SELECTION:
4.1)
INFORMATION SCREENS: display a pre determined parameter which will then appear
each time the tool is started and during the entire work cycle.
F
= 60.0 kN
m
Fp = 24.5 kN
F
= 6.75 ton
m
Fp = 2.75 ton
P
= 661 bar
m
Pp = 312 bar
P
= 9587 psi
m
Pp = 4525 psi
BATTERY
1000
-19000
B500
NR 13AJ002
Fm: Minimum set force, expressed in kN.
Fp: Peak force reached, expressed in kN,
(screen as factory setting)
Fm: Minimum set force, expressed in US sh. tons.
Fp: Peak force reached, expressed in US sh. tons.
Pm: Minimum set pressure, expressed in bar.
Pp: Peak pressure reached, expressed in bar.
Pm: Minimum set pressure, expressed in psi.
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
tool serial no.
F
= 60.0 kN
m
F
= 58.3 kN
p
P
= 661 bar
m
P
= 485 bar
p
max.
BATTERY
LED
ON
LED
OFF
F
= 60.0 kN
m
OK
P
= 661 bar
m
OK
min.
BATTERY