Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 3.1) Touch the buttons [+] or [-] to increase or
decrease the power (minimum = 00 - Maximum = 100). If confirmed with the button [Store] within 5 seconds, the maxi-
mum power will remain that just set. Exit TEST mode (see sec. 3.1).
Service menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE SERVICE MENU AND MODIFY PARAMETERS.
The service menu is accessed via the main user menu (detail 1 fig.1).
1. Access the main user menu
2. Press [Service menu]
3. Confirm the desire to proceed by touching [Confirm]
4. Use the keypad that appears on the screen to enter pin 1234 and touch the confirm button
Description of SERVICE MENU screen
CONNECTED
(11)
Service Menu
Diagnostica impianto
Parametri trasparenti B
Parametri trasparenti P
Controllo combustione
(6)
Parametri ZTP
(7)
Modalità Test
Storico anomalie
Reset storico anomalie
fig. 25- Service Menu
206
Jul 29 2020 14:36
(1)
(2)
(3)
(4)
(5)
(9)
(8)
2
(10)
cod. 3541U630 - Rev. 00 - 07/2020
BLUEHELIX MAXIMA
Back to main user menu
1
Probe and sensor information
2
List of transparent parameters B
3
List of transparent parameters P
4
List of combustion control parameters
5
List of ZTP parameters
6
Access the test mode
7
Number of faults not read since last access to
8
history
Faults history
9
Clear faults history
10
Back to main screen