Ferroli BLUEHELIX MAXIMA Instrucciones De Uso, Instalación Y Mantenimiento página 217

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BLUEHELIX MAXIMA
Fault code
Fault
F17
Fume probe fault
A13
Fume extraction duct safety
A14
device intervention
Optimum water pressure not
A23
reached in foreseen time
Water pressure restored more
A24
than 3 times in 24h
Excessive water pressure
A26
more than 3 times in an hour
Supply voltage under 170V
F34
System water pressure too
F20
low
F37
External probe fault
F39
Activation of maximum
F41
DELTA T protection
System water pressure too
F21
high
F40
Sensor control protection acti-
F36
vation
A42
Exchanger protection inter-
F43
vention.
Water pressure sensor error
F47
Low water pressure with para-
F51
meter b06 = 3
EN
Possible cause
Probe damaged
Wiring shorted
Wiring disconnected
Fault F03 generated 3 times in
the last 24 hours
Water supply trouble
Loading valve blocked in clo-
sed position
Heating system leaks
DHW exchanger damaged
Pressure too high Expansion
vessel empty or damaged
Expansion vessel empty or
damaged
Electric mains trouble
Pressure too low
Water pressure switch/pres-
sure transducer not connected
or damaged
Probe damaged or wiring shor-
ted
Probe disconnected after acti-
vating the sliding temperature
Heating sensor damaged
Return sensor damaged
No water circulation in the sys-
tem
Air in the system
Pressure too high
Filling valve blocked in open
position
Expansion vessel empty or
damaged
Return and/or flow sensor
damaged or disconnected
Return sensor damaged or dis-
connected
No system H
O circulation
2
Air in the system
Water pressure sensor discon-
nected
Water pressure sensor dama-
ged
Pressure too low
Secondary water pressure
switch disconnected or dama-
ged
Incorrect parameter
cod. 3541U630 - Rev. 00 - 07/2020
Cure
Check the wiring or replace the fume probe
See fault F03
Check the connection to the water supply
Check the loading valve and valve control relay
Check for leaks in the heating system
Check the exchanger
Partially drain the system
Check the expansion vessel
Check the electrical system
Fill the system
Check the water pressure switch/pressure
transducer
Check the wiring or replace the sensor
Reconnect the external probe or disable the sli-
ding temperature
Check the correct positioning and operation of
the heating sensor
Check the correct positioning and operation of
the return sensor
Check the circulating pump
Vent the system
Partially drain the system
Check the filling valve and valve control relay
Check the expansion vessel
Check the correct positioning and operation of
the return and/or flow sensor
Check the correct positioning and operation of
the return sensor
Check the circulating pump
Vent the system
Check the water pressure sensor wiring
Check the water pressure sensor
Fill the system
Check the water pressure switch/pressure
transducer
Check the correct parameter setting
217

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bluehelix sublime 28cBluehelix sublime 34c0tsb4fwa0tsb7fwa

Tabla de contenido