Code Description
P62 System filling mode
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the setting of the parameter
given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given in brackets is mo-
dified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
To return to the service menu, simply touch the "arrow" icon
Combustion Control Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE MENU AND MODIFY THE RELEVANT PARAMETERS.
Code
Description
Gas type selection
Sc01
Ignition gas calibration
Sc02
Ignition power
Sc03
Flue length
Sc04
Minimum power calibration
Sc05
Minimum gas valve calibration
Sc06
Flame ionization signal
Sc07
Current power ref. DHW
Sc08
MAX ionization value
Sc09
Minimum ionization value during ignition
Sc10
Ignition time
Sc11
Ionization reduction value (BASE)
Sc12*
Ionization reduction value (min.)
Sc13**
Internal error K1
Sc14
100% CALIBRATION
Sc15
ZTP (Sliding temperature) Parameters Menu
When the external probe is installed, the boiler adjustment system works with "Sliding Temperature". In this mode, the
heating system temperature is regulated according to weather conditions, to ensure high comfort and energy efficiency
throughout the year. In particular, as the outside temperature increases the system flow temperature decreases accor-
ding to a specific "compensation curve".
With Sliding Temperature adjustment, the temperature set using the buttons [+] (detail 12 fig.1) and [-] (detail 14 fig.1)
becomes the maximum system flow temperature. It is advisable to set a maximum value to allow system adjustment
throughout its useful operating range.
The boiler must be adjusted at the time of installation by qualified personnel. However, the user can make any further
adjustments necessary to optimize comfort levels.
210
Range
Manual
Automatic
Functional description
Allows the change of gas type. See "Gas conver-
sion" on page 204
Allows the amount of gas to be increased or decrea-
sed in the ignition phase in case of difficult starting.
Allows the fan speed to be increased or decreased
in the ignition phase in case of difficult starting.
Allows the boiler to be arranged according to the
width and length of the flue used. To be used only
with Ø50 or Ø60 flues. See fig. 20.
Allows the minimum power to be increased, if
necessary.
Self-adaptive parameter. DO NOT MODIFY.
Displays the actual ionization current signal.
Displays the actual power referred to maximum
power in DHW.
Displays the maximum ionization value reached.
Displays the minimum ionization value reached
during the ignition phase.
Displays the time from fan activation to ionization.
NOT MODIFIABLE
NOT MODIFIABLE
Displays the SCOT system error code.
Allows 100% Calibration (see "100% calibration" on
page 205) in case of replacement of several compo-
nents
cod. 3541U630 - Rev. 00 - 07/2020
BLUEHELIX MAXIMA
Default
Manual
in the top left corner of the screen.
Range
Default
NG/LPG
NG
-9 ÷ 20
0
-16 ÷ 14
0
-2 ÷ 13
0
0 ÷ 25
0
Read only
Read only
Read only
Read only
Read only
Read only
0
Read only
0
Read only
0 - 1
0