Fan Operation (Optional); Setting The Cooling Capacity - Dometic 10-Serie Instrucciones De Uso

Ocultar thumbs Ver también para 10-Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90
Using the refrigerator
6.10

Fan operation (optional)

For fan operation the optional fan must be installed.
When switching on the device, the fan is switched on for a short time (function test).
During the device's operation the fan only switches on:
• When the ambient temperature is above 32 °C.
• When the set cooling temperature is not reached within 2 hours.
• RMD10.5T, RMD10.5XT: When the fan function is activated.
I
NOTE
RMD10.5T, RMD10.5XT: In delivery state, the fan function is
activated.
RMD10.5, RMD10.5X, RMD10.5S, RMD10.5XS: The fan function is
always activated and can not be deactivated.
RMD10.5T, RMD10.5XT
The fan operation is indicated by the symbol
6.11

Setting the cooling capacity

I
NOTE
For ambient temperatures of +15 °C to +25 °C, select the average cool-
ing capacity.
➤ Set the cooling capacity:
– RMD10.5T, RMD10.5XT: Select the desired temperature level in the cool-
ing capacity menu.
– RMD10.5, RMD10.5X, RMD10.5S, RMD10.5XS: Repeatedly press
until the desired temperature level is selected.
26
RMD10.5(X)(T)(S)
.
EN

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Rmd10.5xsRmd 10.5xt

Tabla de contenido