Best WC45 Serie Manual Del Usuario página 18

Ocultar thumbs Ver también para WC45 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

WC45E Programming Mode Procedure
WC45E Programming Mode Procedure
The range hood is designed to work with several different blowers models. Before using the
hood, the control must fi rst be programmed to your blower model, in order to achieve proper
operating speed:
1. Find the SETUP number that corresponds to the blower model that is installed with your
range hood.
2. There must be power to the hood but the blower and lights must be turned off.
3. Press key TC2 and TC5 simultaneously for 5 seconds; when the function is activated all
the LEDs switch off, then keys TC2, 3, 4 , 5 activate fl ashing three times; then TC2 key
and the selected speed switch on.
4.In order to store the new setting, press shortly key TC2 or wait 15 seconds. Your setup is
memorized.
5. When the new setting is memorized, key TC2 fl ashes twice and then all the LEDs switch
off
Description of "Speed Level"
Setup 1 is for motors with a rating up to 3.0
amp
Setup 2 is for motors with a rating between
3.1 amp and 5.0 amp
Setup 3 is for motors with a rating greater
than 5.1 amp to 6 amp
SETUP 1 (TC3) SETUP 2 (TC4) SETUP 3 (TC5)
- 19 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wc45e serieWc45iq serie

Tabla de contenido