EXTERNAL BLOWER
PROGRAMMING MODE PROCEDURE (WC34E)
ON
OFF
Light
Light
Off
On
The range hood is designed to work with
several different blower models. Before
using, the control must first be programmed
to your blower model, in order to achieve
proper operating speeds.
From the chart below:
1. Find the SETUP number that
corresponds to the blower model that is
installed with your range hood.
2. The control is factory-preset to SETUP
3. If your blower model is listed under
SETUP 3, no programming is required
and the range hood is ready to use.
SETUP 1
BLOWER
EB6
MODEL
ILB3
NUMBER
ILB6
OFF / -
Blower
Off / Speed
SETUP 2
SETUP 3
(default)
EB12
EB9
EB15
ILB11
ILB9
- 18 -
ON / +
Blower LED
Indicators
Blower
On / Speed
3. To program blower models listed under
SETUP 1 and 2:
A) Power must be supplied to the
hood. The blower and lights must be
turned off.
B) Press and hold OFF and ON/+
for 5 seconds. The Blower LED
Indicators will flash 3 times. Then
only the LED will stay lit. After 1
second, the Blower LED Indicators
will show the current setting as
follows:
°°°
SETUP 1
• •
°
°
SETUP 2
° ° °
SETUP 3
C) To select the proper SETUP:
Press OFF/- or ON/+ to select the
desired SETUP.
D) Once the proper SETUP is found:
Press ON to memorize the setting,
or wait 15 seconds and the program
will automatically exit and store the
SETUP.
E) The range hood is now ready to use.
R
LED
Time Delay /
Filter Clean
Reset
FIG. 25