4.3

Mode of operation

Shut-off valves are used for shutting off and/or throttling media.
Install shut-off valves so that the spindle is vertical and the medium
enters under the cone.
The shut-off valve is opened or closed by turning the hand wheel or
actuating the drive. Tools for increasing handwheel torque are not
allowed.
4.4

Operating data

Valve
01420
01423
4.5
Media
Gases, cryogenic liquefied gases and their gas mixtures, such as:
Name
Argon,
Chlorotrifluoromethane,
Nitrous oxide,
Ethane,
Ethylene,
Carbon dioxide,
Carbon monoxide,
Krypton,
LNG,
LPG,
Methane,
Oxygen,
Nitrogen,
Trifluoromethane,
Hydrogen,
24
All manuals and user guides at all-guides.com
Operating instructions
Rated
Temperature
pressure
-196 °C to
PN 50
+120 °C
Phone +49 4531 509-0
Close
Max. operating pressure
50 bar
Open

Publicidad