Daitsu DS-18UIAK Manual Del Usuario página 41

Ocultar thumbs Ver también para DS-18UIAK:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Notices for installation
1. The air inlet and outlet should be away from the obstructions. Ensure the air can be blown
through the whole room.
2. Select a site where the condensate can be easily drained out, and where it is easily
connected to outdoor unit.
3. Select a place where it is out of reach of children.
4. Select a place where the wall is strong enough to withstand the full weight and vibration
of the unit.
5. Be sure to leave enough space to allow access for routine maintenance. The installation
site should be 250cm or more above the floor.
6. Select a place about 1m or more away from TV set or any other electric appliance.
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit is installed in accordance with installation dimension
instructions.
9. Do not use the unit in the laundry or by swimming pool etc.
1. Select a site where noise and outflow air emitted by the unit will not annoy neighbors.
2. Select a site where there is sufficient ventilation.
3. Select a site where there is no obstruction blocking the inlet and outlet.
4. The site should be able to withstand the full weight and vibration.
5. Select a dry place, but do not expose the unit to direct sunlight or strong wind.
6. Make sure that the outdoor unit is installed in accordance with the installation instructions,
and is convenient for maintenance and repair.
7. The height difference between indoor and outdoor units is within 5m, and the length of
the connecting tubing does not exceed 10m.
8. Select a place where it is out of reach of children.
9. Select a place where the unit does not have negative impact on pedestrians or on the city.
Safety Precautions for Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety
regulations.
2. Don't drag the power cord with excessive force.
3. The unit should be reliably earthed and connected to an exclusive earth device by the
professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent
short circuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6. The appliance shall be installed in accordance with national wiring regulations.
7. An all-pole disconnection switch with a contact separation of at least 3mm in all poles
should be connected in fixed wiring.
Note:
Make sure the live wire, neutral wire and earth wire in the family power socket are properly
connected. There should be reliable circuit in the diagram.
Inadequate or incorrect electrical connections may cause electric shock or fire.
All manuals and user guides at all-guides.com
Installation Site of Indoor Unit
Installation Site of Outdoor Unit
- 19 -

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Dos-18uiak

Tabla de contenido