Performing the measurement
1
Turn on the amplifier.
2
Press MENU.
3
Press v to display "<2-Auto
Calibration>," then press
enter the menu.
4
Press v to display "CAL TYPE,"
then press
parameter.
5
Press V/v to select the
parameter, then press
enter the selection.
Calibration
type
ENGINEER
FULL FLAT
6
Press V to display "AUTO CAL
START?," then press
start the measurement.
The measurement starts in five seconds. A
countdown appears on the display.
While the time is counting down, stand
away from the measurement area to
avoid measurement error.
7
The measurement starts.
The measurement process will take
approximately 10 seconds. Wait until the
measurement process completes.
Tip
When special speakers, such as dipole speakers, are
used, the measurements may not be performed
correctly or auto calibration cannot be performed.
14
GB
to enter the
to
Explanation
Sets the frequency
characteristics to a set that
matches that of the Sony
listening room standard.
Makes the measurement of
frequency from each
speaker flat.
to
To cancel the measurement
The measurement is cancelled when you
change the volume, change the input source,
press MUTING, or connect headphones.
Confirming/saving the
measurement results
to
1
Confirm the measurement
result.
When the measurement ends, a beep
sounds and the measurement result
appears on the display.
Measurement
result
When the
measurement
process
completes
properly
When the
measurement
process fails
2
Press V/v repeatedly to select
the item, then press
Item
RETRY
SAVE EXIT
WRN CHECK
EXIT
Display
Explanation
COMPLETE Proceed to step
2.
ERROR
See "When
CODE 3x
error codes
appear" (page
15).
.
Explanation
Re-performs the
measurement.
Saves the measurement
results and exits the setting
process.
Displays a warning
concerning the
measurement results. See
"When you select "WRN
CHECK"" (page 15).
Exits the setting process
without saving the
measurement results.