THE INTERFACE
On/Off Key on panel
To switch the stove on and off, to exit from the setting menu.
"Menu" Key on the panel
Press for 2 seconds to switch on start time setting and programmed stop.
Press briefly to switch from Manual to Automatic stove function. Also allows regulation Air ventilation level adjustment (use +/-
to vary the selected mode).
Messages displayed on the screen
Ac: ignition stage (flame)
Ar: second stage of ignition (flame stabilizing) before the operating stage
Of: shutdown stage (duration: 10 minutes)
P1 or P2 or P3: power setting
10-30: temperature setting for automatic operation
Air 1-9: ventilation level setting
H1..H7: arrest whit error message (see page 22)
Pu: automatic combustion chamber cleaning in process
ŋŋ: motor stopping, wait for a few tens of seconds before entering other commands.
When the stove is on standby, it displays the mode of operation with which it will restart and the time (flashing).
OPERATION
Before starting.
First ignition: consult your DEALER; they will adjust the stove to suit the type of pellets used and the installation conditions.
A slight smell of paint may be detected the fi rst few times the stove is started, but it quickly disappears.
Before starting check:
- that the stove has been installed correctly (see Pages 17-18)
- the power supply
- that the door is closed
- that the combustion chamber is clean
- standby is shown on the display (flashing power or temperature).
Hold the ON/OFF key down for at least 2 seconds; the stove will automatically start loading pellets for combustion (Ac appears
on the display). No flame appears for the first few minutes.
The message Ac is replaced by Ar when the flame appears.
SCREW FEEDER LOADING.
Any time the pellet tank is fully empty, press the + key followed by the Menu key for a few seconds to fill the screw feeder.
This operation must be carried out before ignition if the stove ceased operating because it had run out of pellets.
It is normal for a few pellets, which the screw feeder is not able to pick up, to remain in the hopper.
The screw feeder filling phase will deactivate automatically after approximately 4 seconds, when the pellets begin to fall in the
crucible. The refilling phase can be stopped manually by pressing the "ON/OFF" key.
IGNITION

Automatic ignition

Hold the ON/OFF key down for two seconds with the stove on standby to start the ignition procedure. Ac will appear on the
display for a few minutes. The ignition procedure does not have a set duration: it is automatically shortened if the electronics
detect that certain tests have been passed. The flame appears after about 5 minutes. It is normal for a bit of smoke to develop in the
combustion chamber before the flame appears. Ar then appears until the flame is stable.
- 20
-