_RV-26.book Seite 32 Montag, 7. Mai 2007 2:28 14
Information on the electrical connections
6.2
Using branch connectors
To prevent loose connections in the branch connectors, it is important to en-
sure that the cable cross sections fit into the branch connectors.
To use the branch connectors, proceed as follows:
➤ Insert the cable to be tapped in the front groove of the cable connector
(fig. a A, page 6).
➤ Insert the end of the new cable up to approx. 3/4 of the way into the rear
groove (fig. a B, page 6).
➤ Use a pair of combination pliers to close the connector by pressing the
metal pin in. This creates an electrical connection (fig. a C, page 6).
➤ Press down the safety cap until it snaps into place.
➤ Check that the connection is secure by lightly tugging the cable (fig. a D,
page 6).
6.3
Creating clean soldering joints
Proceed as follows to solder a cable to the original cables:
➤ Strip approx. 10 mm of insulation from the end of the original cable
(fig. b A, page 6).
➤ Strip approx. 15 mm of insulation from the end of the cable to be connect-
ed (fig. b B, page 6).
➤ Wind the cable to be connected around the original cable and solder the
two cables together (fig. b C, page 6).
➤ Insulate the two cables with insulating tape (fig. b D, page 6).
Proceed as follows to solder two cables together:
➤ Strip the two cables (fig. c A, page 6).
➤ Place a shrink sleeve with a length of approx. 20 mm over the cable
(fig. c B, page 6).
➤ Twist the cables together and solder them (fig. c C, page 6).
➤ Place a shrink sleeve over the soldered point and heat it briefly (fig. c D,
page 6).