Fit a plug suitable for the load on the power lead and connect it to a suitable safety
If you wish to make a direct connection to the mains, an omni polar switch with a gap
between the contacts of at least 3 mm, of suitable rating for the load and complying
with the regulations in force, must be installed between the appliance and the mains.
The switch must not break a contact in the yellow/green earth wire.
The brown live wire (connected to the "L" terminal of the terminal board) must
always be connected to the live wire of the power supply mains.
In all cases, the power supply lead must be positioned so that it does not reach a
temperature 50
One example of an ideal route is shown in the illustration. The cable is guided by
means of band clamps fixed to the side of the cabinet, in order to avoid any contact
Replacing the power supply lead
If the lead has to be replaced, only HO5RR-F or
HO5RN-F type cables suitable for the load and the
operating temperature must be used. In addition, the
yellow/green earth wire must be about 2 cm longer than
the live and neutral wires.
Adapting to the different types of gas
12) Remove the burner caps and flame caps from the burners.
13) Use a size 7 socket wrench to unscrew and remove the
nozzles, replacing them with those corresponding to the
type of gas to be used (see the table ).
14) Reassemble the parts, reversing the operations described
15) Then replace the setting data (close to the mains gas
connection)with the one for the new type of gas If the pressure of the gas used is
different from that specified(or variable),a suitable piped gas pressure regulator
complying with the standard must be installed on the supply pipeline.
socket.
o
C above the room temperature
with the appliance underneath the hob.
Changing the nozzles
11) Remove the pan standee.
above.
at
any point.