Make the Electric
Connections
WARNING: To avoid possible electrical shock, be
sure electricity is turned off at the main fuse box
before wiring.
WARNING: Fan must be installed at a maximum
distance of 20 feet from the transmitting unit for
proper signal transmission between the transmitting
unit and the fan's receiving unit.
If you feel you do not have enough electrical wiring
knowledge or experience, have your fan installed by
a licensed electrician.
Step 1. Connect green wires from EMI filter and
related parts according to the wiring diagram as
shown in Figure 13, make sure EMI filter is
properly seated in outlet box.
Step 2. Place the EMI filter into the ceiling box
before installing the receiver into the bracket. Insert
the receiver into the mounting bracket with the flat
side of the receiver facing the ceiling. (Fig. 12)
Step 3. Motor to receiver electrical connections:
Connect the grey wire from the fan to the grey wire
from the receiver. Connect the red wire from the fan
to the red wire from the receiver. Connect the
yellow wire from the fan to the yellow wire from
the receiver. (Fig.13)
Step 4. Receiver to house supply wires electrical
connections: Connect the black (hot) wire from the
ceiling to the black wire marked "AC IN L" from
the receiver. Connect the white (neutral) wire from
the ceiling to the white wire marked "AC IN N"
from the receiver. (Fig.13)
Secure all wire connections with the plastic wire
nuts provided
Figure 12
AC IN L(Black)
AC IN N(White)
Ground wire
EMI Filter
Ground wire
Ground wire
Ground wire
Gray
Yellow
Red
Gray
Red
Yellow
Ground wire
Figure 13
EMI Filter
Hanger bracket
6.