Descargar Imprimir esta página

Beko QWIK-PURE 200 Instrucciones De Montaje Y De Uso página 18

Ocultar thumbs Ver también para QWIK-PURE 200:

Publicidad

Putting into operation • Puesta en marcha
Mise en service • Colocação em funcionamento
1
Utilisation • Operação

2
water
agua
eau
água
Operation • Servicio
OEKOSORB-Filter
The QWIK-PURE oil-water separator
supplied by the manufacturer is equipped
with a OEKOSORB filter set.
Check the correct seat of the OEKO-
SORB filters before putting the unit into
service:
- Open container lid.
- The handles of the main filter must be
locked into place on the inner wall.
- When closing the housing lid, fit the
prefilter onto the guide pipe.
Fill QWIK-PURE with clean water
3
• Fill water into the main container
• Shut off water when it starts to come
out at the water outlet.
The water level will sink due to the gradual
water intake of the filter.
• Fill up with clean water as required.
The QWIK-PURE is ready for operation:
• Compressor condensate can now flow
into the QWIK-PURE via the pressure
relief chamber.
Note:
Open the outlet of the condensate
drain!
Check all connections for leaks!
The service valve is closed during ope-
ration.
To ensure trouble-free operation, ob-
serve all the points listed under Main-
tenance:
Note:
The constituents of the compressor
condensate will depend on the specific
application.
It is part of the operator's duty of care to
take the necessary precautions, where
appropriate.
english
english
QWIK-PURE 200, 350

Publicidad

loading

Este manual también es adecuado para:

Qwik-pure 350