OPERATING INSTRUCTIONS
1. Preparing for Startup
WARNING: Risk of bursting. Too much air
pressure causes a hazardous risk of bursting. Check the
manufacturer's maximum pressure rating for air tools and
accessories. The regulator outlet pressure must never
exceed the maximum pressure rating
a. Set the ON/OFF switch (B) to the 0 (off) position.
b. Turn the air pressure regulator knob (F) counter-
clockwise until it stops.
c. Attach air hose/accessories or air tools (not
included) to the air-line outlet (C).
2. Starting up the Compressor
WARNING: High temperatures are generated by
the electric motor and the pump. To prevent burns or
other injuries, DO NOT touch the compressor while it
is running. Allow it to cool before handling or servicing.
Keep children away from the compressor at all times.
WARNING: When adjusting from a higher to a
lower pressure, turn the knob counterclockwise past the
desired setting. Then turn clockwise to reach the desired
pressure. Do not exceed operating pressure of the tool or
accessory being used.
a. Close the tank drain valve (I) by turning
clockwise.
b. Plug in the power cord (J).
c. Set the ON/OFF switch (B) to the I (on) position
and allow tank pressure to build. Motor will stop
when tank pressure reaches "cut-out" pressure.
d. Turn the air pressure regulator knob (F) clockwise
until desired pressure is reached.
e. The compressor is ready for use.