Data And Marking; Storage; Installation; Commissioning - Wega MININOVA CLASSIC DUO Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91

Data and marking

2.6
The machine technical data are listed in the follow-
ing table:
Voltage
Max power
ROSSO
C:0 M:100 Y:100 K:0
NERO
C:0 M:0 Y:0 K:100
Steam boiler capacity
VERDE
C:100 M:0 Y:100 K:0
Safety valve calibration
Boiler operating pressure
Feed water pressure
Coffee dispensing pressure
Operating conditions
Sound pressure level
According to the Directive 2006/42/EC, the machine is
marked with the CE marking, by which the manufacturer
declares, under its own responsibility, that the machine
is safe for people and things.
The CE nameplate is affixed to the base of the frame
under the drain pan on which the identification data is
reported. Below is an example of the nameplate:
MARCHIO COMMERCIALE
WEGA MACCHINE PER CAFFÈ S.r.l.
Via C. Bardini,1 SUSEGANA (TV) - ITALY
Tel. +39.0438.1799700 Fax +39.0438.1884890
S/N:
V
For any communication with the Manufacturer, al-
ways note the following information:
• S/N - machine serial number;
• Mod. - machine model
• Y - date of manufacture;
The data of the appliance can be seen also on the
label located on the package of the machine.
It is forbidden to remove or damage the nameplate. If it needs
replacing urgently, always exclusively contact the Manufacturer.
36
160
of
230-240 V
1.600 W
2 L
0,19 MPa (1,9 bar)
0,08 - 0,14 MPa (0,8 - 1,4 bar)
0,15 - 0,6 MPa max (1,5 - 6 bar max)
0,8 - 0,9 MPa (8 - 9 bar)
5 - 35°C
95° U.R.MAX
< 70 dB
Y
Mod.
Hz
W
MADE IN ITALY
Q
3.

STORAGE

The machine is stored by the Manufacturer or the
Distributor.
4.

INSTALLATION

The installation of the machine must be performed
only by the Maintenance Technician.
During the installation the Maintenance Technician needs to
renewal operations of the water contained in the hydraulic circuits.
The base of the machine support must be perfectly level and
without irregularities.
The electric system must be equipped with a suitable differential
circuit breaker (30 mA).
5.

COMMISSIONING

The commissioning of the machine must be per-
formed only by the Maintenance Technician.
2
5
The CE nameplate is fixed on
the base of the frame under
the drain pan.
USER manual

Publicidad

Tabla de contenido
loading

Tabla de contenido