2. Safety / 3. Specifications
2.4 Labelling, safety marking
Product label
TFS135
Model
Contact design (NC = normally closed)
Nominal switching temperature
Number of production order
Approval logos
Before mounting and commissioning the instrument,
ensure you read the operating instructions!
3. Specifications
Rectangular connector per DIN EN 175301-803
Switching voltage:
Medium temperature range:
Ambient temperature range:
Pressure load:
Circular connector M12 x 1
Switching voltage:
Medium temperature range:
Ambient temperature range:
Pressure load:
WIKA operating instructions model TFS135
All manuals and user guides at all-guides.com
NC 60 °C
AC 120 V / 60 Hz / 5 A
AC 250 V / 50 Hz / 2.5 A
-30 ... +130 °C
-30 ... +85 °C
max. 50 bar
AC 120 V / 60 Hz / 1 A
AC 250 V / 50 Hz / 1 A
-25 ... +130 °C
-25 ... +55 °C
max. 50 bar
12345678
9