E E M M C C i i n n f f o o r r m m a a t t i i o o n n
W W A A R R N N I I N N G G - - The use of accessories, transducers, and cables, other than those specified or provided by the manufacturer,
could result in increased electromagnetic emissions or decreased electromagnetic immunity and result in improper
operation.
N N o o t t e e
• The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals (CISPR 11
class A). If it is used in a residential environment (for which CISPR 11 class B is normally required) this equipment might
not offer adequate protection to radio-frequency communication services. The user might need to take mitigation
measures, such as relocating or re-orienting the equipment.
• This equipment is suitable for use in hospitals except for near active HF surgical equipment and the RF shielded room of
an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high.
G G u u i i d d a a n n c c e e a a n n d d m m a a n n u u f f a a c c t t u u r r e e r r ' ' s s d d e e c c l l a a r r a a t t i i o o n n - - e e l l e e c c t t r r o o m m a a g g n n e e t t i i c c e e m m i i s s s s i i o o n n s s
The 2874 I I s s o o T T o o u u r r pump is intended for use in the electromagnetic environment specified below. The customer or the
user of the 2874 I I s s o o T T o o u u r r pump should assure that it is used in such an environment.
E E m m i i s s s s i i o o n n s s t t e e s s t t
RF Emissions
CISPR 11
RF Emissions
CISPR 11
Harmonic Emissions
IEC 61000-3-2
Voltage Fluctuations
Flicker Emissions
IEC 61000-3-3
W W A A R R N N I I N N G G
• Portable RF communications equipment, including peripherals such as antenna cables and external antennas, should
be no closer than 12 inches (30 cm) to any part of I I s s o o T T o o u u r r , including cables specified by the manufacturer.
• Avoid stacking or placing equipment adjacent with other equipment to prevent improper operation of the products. If
such use is necessary, carefully observe stacked or adjacent equipment to make sure that they are operating properly.
R R e e c c o o m m m m e e n n d d e e d d s s e e p p a a r r a a t t i i o o n n s s d d i i s s t t a a n n c c e e s s b b e e t t w w e e e e n n p p o o r r t t a a b b l l e e a a n n d d m m o o b b i i l l e e R R F F c c o o m m m m u u n n i i c c a a t t i i o o n n e e q q u u i i p p m m e e n n t t a a n n d d t t h h e e 2 2 8 8 7 7 4 4
The 2874 I I s s o o T T o o u u r r pump is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the 2874 I I s s o o T T o o u u r r pump can help prevent electromagnetic interferences by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the
2874 I I s s o o T T o o u u r r pump as recommended below, according to the maximum output power of the communications
equipment.
B B a a n n d d ( ( M M H H z z ) )
2874-009-005 Rev A.0
C C o o m m p p l l i i a a n n c c e e
Group 1
Class A
Class A
Complies
I I s s o o T T o o u u r r p p u u m m p p
S S e e r r v v i i c c e e
E E l l e e c c t t r r o o m m a a g g n n e e t t i i c c e e n n v v i i r r o o n n m m e e n n t t
The 2874 I I s s o o T T o o u u r r pump uses RF energy only for its
internal function. Therefore, its RF emissions are
very low and are not likely to cause any interference
in nearby electronic equipment.
The 2874 I I s s o o T T o o u u r r pump is suitable for use in all
establishments other than domestic and those
directly connected to the public low voltage power
supply network that supplies buildings used for
domestic purposes.
M M a a x x i i m m u u m m P P o o w w e e r r
( ( W W ) )
M M i i n n i i m m u u m m S S e e p p a a r r a a t t i i o o n n D D i i s s t t a a n n c c e e
( ( m m ) )
21
EN