Xylem rule 360-1100 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
All manuals and user guides at all-guides.com
Installation:
Push tabs on either side of the pump to remove pump from the base.
We recommend using #8 stainless steel flathead screws of an adequate length as
to secure the pump but not penetrate the entire thickness of the hull. Use a flexible
sealant in the screw holes to prevent water from penetrating the screw holes.
Insert the pump into the base and push down until an audible
"click" is heard.
Flow - GPH (LPH)
@ Oft
GPH
Series
Om -0 kPa
360
417.3 (1579)
500
572 (2165.2)
800
1045 (3955)
1100
1116 (4224)
Height
Standard Pumps
360/500
3.9" (10cm)
800/1100 4.4" (11.2cm)
Electronic Sensing
360/500 4.2" (10.7cm)
800/1100 4.7" (12cm)
We hereby declare, under our sole responsibility, that our product
to which this declaration relates has been designed to comply in
accordance with the following Directives:
Electromagnetic Compatibility Directive 2014/30/EU
Recreational Craft Directive 2013/53/EU
RoHS 2011/65/EU.
With the relevant selections of the following Standards:
ISO 8846: (EN 28846): Ignition Protection
ISO/EN 8849: Electrically Operated DC Bilge Pumps
ISO 10133:2012 / Extra Low Voltage D.C. Installations
ISO 15083:2003 / Bilge Pumping Systems
@ 3.3 ft
@ 6.7 ft.
1 m -10 kPa
2m-20 kPa
308 (1165)
150 (567.81) 12' (3.7m)
470 (1779.1)
270 (1022.1) 11' (3.4m)
790 (2990.5)
575 (2175)
1005 (3804.3)
825 (3123)
See Height
Chart
2.5"
(6.4cm)
All mounting holes must be sealed with a
marine grade sealant to prevent water intrusion.
Install to ABYC
H-22 and E-11
7
Max Head
Height
12' (3.7m)
10' (3m)
2.9"
7.4cm)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rule 360 gphRule 1100 gph

Tabla de contenido