9.
Decommissioning
9.1
Temporary shutdown
In the event of lengthy periods of non-use:
¶
Disconnect VLH 2140 from the mains voltage system.
¶
Lock the main switch.
9.2
Change of location
¶
Disconnect electrical and pneumatic connections.
¶
The VLH 2140 is only ever to be transported in the
original or equivalent packaging.
¶
If the VLH 2140 is passed on, all the documentation
included in the scope of delivery must be handed over
together with the unit.
¶
Heed the notes on initial commissioning.
9.3
Disposal and scrapping
9.3.1
Substances hazardous to water
!
Oils and greases as well as refuse containing oil and
grease (e.g. filters) represent a hazard to water.
1. Substances hazardous to water must not be allowed
to enter the sewage system.
2. Substances hazardous to water must be disposed of
in accordance with the applicable regulations.
9.3.2
VLH 2140 and accessories
1. Disconnect the VLH 2140 from the mains and detach
the power cord.
2. Dismantle the VLH 2140 and sort out and dispose
of the different materials in accordance with the
applicable regulations.
VLH 2140, accessories and packaging should
be sorted for environmental-friendly recycling.
¶
Do not dispose VLH 2140 into household
waste.
Only for EC countries:
The VLH 2140 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
¶
Make use of the local return and collection
systems for disposal.
¶
Proper disposal of VLH 2140 prevents
environmental pollution and possible health
hazards.
Beissbarth GmbH
Decommissioning | VLH 2140 | 37
10. Technical data
10.1
Ambient conditions
10.1.1
Use
Property
Temperature
Humidity
10.1.2
Storage and transportation
Property
Temperature
Humidity
10.2
Lift performance data
Property
Load-bearing capacity
Load distribution
(as per standard EN 1493:2010)
Lifting height
Effective lift
Lifting time
Lowering time
Lifting speed
Lowering speed
10.3
Operating data
10.3.1
Electric power (lift)
Property
Phases
Rated voltage
Frequency
Protection
Rated current
Rated power
Max. power / current
R With working sockets
Control voltage
Operating factor
Type of protection
Degree of protection
en
Value/Range
5 °C – 45 °C
41 °F – 113 °F
20 % - 80 %
Value/Range
-25 °C – 45 °C
-13 °F – 113 °F
30 % – 60 %
Value / range
4000 kg
Max. 3 : 1 in both
directions
1851 mm
1750 mm
39 s
24 s
45 mm/s
73 mm/s
Value / range
3P / N / PE
400 V AC
50 Hz
16/3/B
5.5 A
2.2 kW
R 3.6 kW / 16 A
230 V AC
S3 -10 %
IP 54
/ II
|
1 692 826 073
2017-03-29