Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

READ INSTRUCTIONS CAREFULLY: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and
follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has
not read these instructions to assemble, light, adjust or operate the heater.
Heatstar ERSP
Gas-Fired Low-Intensity Infrared Heaters Approved
For Residential Garage/Commercial Applications
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation, operating and maintenance instructions
thoroughly before installing or servicing this equipment.
- WHAT TO DO IF YOU SMELL GAS
• Open Windows
• DO NOT try to light any appliance.
• DO NOT use electrical switches.
• DO NOT use any telephone in your house. Immediately call your local gas supplier from a telephone remote from the
area of the leak. Follow the gas supplier's instructions.
• Do not touch any electrical switch; do not use any phone in your building.
• Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
• If you cannot reach your gas supplier, call the Fire Department.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
OPERATING INSTRUCTIONS
AND OWNER'S MANUAL
ENERCO Group, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194
Model #
ERSP-40
ERSP-60
ERSP-80
ERSP-100
ERSP-125 ERSP-150
ERSP-175
LANGUAGES INCLUDED
•ENGLISH
•FRENCH
•SPANISH
02701

Publicidad

Tabla de contenido
loading

Resumen de contenidos para HeatStar ERSP-40

  • Página 1 OPERATING INSTRUCTIONS Model # ERSP-40 ERSP-60 ERSP-80 ERSP-100 AND OWNER’S MANUAL ERSP-125 ERSP-150 ERSP-175 READ INSTRUCTIONS CAREFULLY: YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS Read and follow all instructions. Place instructions in a safe place for future reference. Do not allow anyone who has not read these instructions to assemble, light, adjust or operate the heater.
  • Página 2 Consult local building inspectors, Fire Marshals or your local Enerco Group, Inc Factory Representative for guidance. Heatstar ERSP heaters are installed on the basis of information given in a layout drawing, which together with the cited codes and regulations, comprise the basic information needed to complete the installation.
  • Página 3 The following codes and instructions should be followed when airborne material or vapor, consult the local Fire Marshal, the planning the installation of the Heatstar ERSP heater. In addition fire insurance carrier or other authorities for approval of the to these instructions, the warnings in (Section 1) must be carefully proposed installation.
  • Página 4 TABLE 1 gives minimum acceptable clearances to combustibles. Clearances as shown in TABLE 1 are not for use in four-sided enclosures. Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 5 45 DEGREE REFLECTOR TILT STANDARD REFLECTOR U-TUBE OPPOSITE 45 DEGREE U-TUBE STANDARD “U”-Tube, Standard “U”-Tube, Opposite 45° “U”-Tube, Full 45° Front and Back Clearance FRONT AND BACK CLEARANCE U-TUBE FULL 45 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 6 TUBE HANGER (14585P) REFLECTOR 10' (00418A) HEAT EXCHANGER TUBE 10' (06413) TURBULATOR BAFFLE 10' (03445) TURBULATOR BAFFLE 5' (03447) **NOT INCLUDED WITH ALL MODELS** **ONLY HEATERS 30' LENGTH AND UNDER** Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 7: Installation Procedure

    “point” in the same direction. Vent Adapter Used to attach the heat exchanger tubing to vent pipe. Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 8 FIGURE 2A: Ener-Radiant SP Model ERSP-40 10 ft. Exchanger length. 11 ft. - 4 in. Total Heater length. 2 Suspension points as indicated. HANGER HANGER 18" 18" (46cm) (46cm) 10' 2½" (3.11m) ALUMINIZED 9' (2.75 m) Long Turbulator Section FIGURE 2B: Ener-Radiant SP Model ERSP-60, ERSP-80, Assembly Overview 20 ft.
  • Página 9 (46cm) (46cm) (46cm) 10' 2½" (3.11m) 10' 2½" (3.11m) 10' 2½" (3.11m) 10' 2½" (3.11m) 10' 2½" (3.1 1m) 10' 2½" (3.1 1m) ALUMINIZED ALUMINIZED ALUMINIZED ALUMINIZED ALUMINIZED ALUMINIZED Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 10 15' (4.57 m) - 25' (7.62 m) ERSP-175 175,000 50 ft. (15.25 m) None 61 ft. 4" (18.69 m) 15' (4.57 m) - 25' (7.62 m) ERSP-175 175,000 60 ft. (18.3 m) None E-10 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 11 Assembly When assembling coupling note the location of Hole 1 and Hole 2 (43cm) Plain Coupling - 14612 Key for Coupling - 14616 U-Tube Fitting Dimensions 180° U-Tube E-11 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 12 Insert tube 06413 into front casting to point (A). Tighter all set screws marked (B) until snug. After both set screws are snug, turn each additional 1/4 turn to secure tube in place. E-12 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 13 2. Reflector to be of aluminum material and designed to direct all radiant output below horizontal center line of radiant tube. 3. Heaters shall be vented according to manufacturer’s recommendations. E-13 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 14 All flue joints should be sealed using suitable product such as ERSP-175 D = 10" (25.4 cm) D = 10" (25.4 cm) D = 8" (20.5 cm) E-14 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 15: Side View

    Vent Adapter Stk. #19021 Vent Adapter Stk. #19021 Burner Box Burner Box Burner Box Burner Box 4” Aluminized steel Heat Exchange Tube 4” Aluminized steel Heat Exchange Tube E-15 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 16 Pitch flue pipe down toward outlet 1/4" per foot (0.6 cm per 0.3m) for condensate drainage. 2"(5cm) Clearance thimble 2"(5cm) Clearance thimble required when flu pipe extends through combustible materials E-16 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 17: Important

    2" 12" Heater Movement Heater Movement 0° 1/2" Stainless Steel Flex Gas Connector Heater Movement Heater Movement Stk. #16401 45° 45° 90° E-17 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 18: Sequence Of Operation

    Igniter Wire Is 16 AWG / 25 KVDC / 10 KVDC All Quick Connects Are Fully Insulated (Except Igniter) Crimp Caps Are # CE5 / 105 Degrees C E-18 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 19 • LP inlet pressure should be 1 1.0” (2.74 kPa) • LP outlet pressure at manifold should be 10.5” (2.61 kPa) 3. Check for proper orifice and air plate. E-19 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 20 The valve will be turned off immediately, and the combustion blower will be turned off following the optional post purge period. E-20 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 21 Check the continuity of the ground wire. for heat ends? Check the thermostat. Replace igniter If a problem still exists, contact Heatstar, Inc Technical Products Customer Service 1-866-447-2194 E-21 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 22 Parts List for Ener-Radiant SP Tube Heaters ERSP-40 Item Stock # Description Item Stock# Description F102594XL ERSP-40 NG / BRN & Cont Box 02753 Front Flange F102595XL ERSP-40 LP / BRN & Cont Box 00419 Reflector End Cap F106408XL Tube Set- 10'...
  • Página 23 ERSP-100, / Tube Set- 30' 14616 Key for Tube Coupling 06413 Tube H.E. 4" O.D. X 10' 00419 Reflector End Cap 00418A Reflector 09369 Spring Clips 03447 Turbulator Baffle 5' 14585P Hanger E-23 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 24 14585 Hanger F102661XL ERSP-175 LP / BRN & Cont Box 00419 Reflector End Cap F106407XL Tube Set- 50' 09369 Spring Clips 06413 Tube H.E. 4" O.D. X 10' E-24 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 25 LP TO NG 1 1739 NG TO LP ERSP-150 1 1740 LP TO NG 1 1741 NG TO LP ERSP175 1 1730 LP TO NG 1 1731 NG TO LP E-25 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 26 125K AIR PLATE 10414A 150K-175K PRESSURE SWITCH 05503XL 150K AIR PLATE 07376 BLOWER MOTOR 05796 150 NG ORIFICE 05508XL 175K AIR PLATE 05794 40K NG ORIFICE 05728 150 LP ORIFICE E-26 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 27 NOTES : E-27 Enerco | Heatstar ERSP Series Heater Operating Instructions and Owner’s Manual...
  • Página 28: Parts Ordering Information

    The company warrants this product to be free from imperfections in material or workmanship, under normal and proper use in accordance with instructions of the Heatstar Company, for a period of 10 years from the date of delivery to the buyer with the following exceptions.
  • Página 29: Pour Votre Sécurité

    INSTRUCTIONS D'UTILISATION No de modèle ERSP-40 ERSP-60 ERSP-80 ERSP-100 ET MANUEL DU PROPRIÉTAIRE ERSP-125 ERSP-150 ERSP-175 : VOTRE SÉCURITÉ EST IMPORTANTE POUR VOUS ET VEUILLEZ LIRE ATTENTIVEMENT LES INSTRUCTIONS POUR LES AUTRES. Lire et observer toutes les instructions. Conserver ces instructions dans un endroit sécuritaire pour vous y référer ultérieurement.
  • Página 30: Responsabilité De L'installateur

    De plus, vérifiez pour tout dommage externe aux boîtes. Prenez note de toute pièce manquante, ou de tout dommage externe aux boîtes, sur le connaissement en présence du conducteur Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 31 Les codes et instructions suivants doivent être suivis lors de la matériaux aériens combustibles, consultez le service des incendies planification de l'installation de la fournaise Heatstar ERSP. En plus local, la compagnie d'assurance-incendie ou les autres autorités de ces instructions, les avertissements à la (Section 1) doivent être pour l'approbation de l'installation proposée.
  • Página 32 Le TABLEAU 1 indique les espaces libres acceptables minimum aux combustibles. Les espaces libres indiqués dans le TABLEAU 1 ne sont pas pour être utilisé dans des enceintes sur les quatre côtés. Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 33 45 DEGREE REFLECTOR TILT STANDARD REFLECTOR U-TUBE OPPOSITE 45 DEGREE U-TUBE STANDARD “U”-Tube, Standard “U”-Tube, Opposite 45° “U”-Tube, Full 45° Front and Back Clearance FRONT AND BACK CLEARANCE U-TUBE FULL 45 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 34 TUBE D'ÉCHANGEUR DE CHALEUR 3,05 M (10 PI) (06413) DÉFLECTEUR TURBULATEUR 1,5 M (5 PI) (03445) DÉFLECTEUR TURBULATEUR 3 M (10 PI) (03447) **NON INCLUS AVEC TOUS LES MODÈLES** Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 35: Procédures D'installation

    « pointer » dans la même direction. Adaptateur d'évent Utilisé pour fixer le tube d'échangeur de chaleur à la conduite d'évent. Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 36 FIGURE 2A : Aperçu de l'assemblage Ener-Radiant modèle ERSP-40 Longueur de l'échangeur de 3,0 m (10 pi). Longueur totale de la fournaise de 3,35 m (11 pi) 10 cm (4 po) . 2 points de suspension comme indiqué. SUPPORT SUPPORT 18"...
  • Página 37 10' 2½" (3.1 1m) 10' 2½" (3.11m) 10' 2½" (3.1 1m) 10' 2½" (3.1 1m) 10' 2½" (3.1 1m) EN ALUMINIUM EN ALUMINIUM EN ALUMINIUM EN ALUMINIUM EN ALUMINIUM EN ALUMINIUM Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 38 50 pi (15.25 m) Aucune 61 pieds 4 pouces (18.69 m) 15 pi (4.57 m) - 25 pi (7.62 m) ERSP-175 175,000 60 pi (18.3 m) Aucune F-10 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 39 1 et 2 (43cm) Couplage (moins la clé) - 14612 Clé pour couplage - 14616 Tube en U à 180° Dimensions du raccord du tube en U F-11 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 40 1) Insérez le tube 06413 dans le moulage avant au point (A). 2) Serrez les vis marquées (B). 3) Après que toutes les (3) vis soient serrées, tournez-les d'un F-12 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 41 2. Le réflecteur doit être d'aluminium et conçu pour diriger toute la sortie radiante sous la ligne centrale horizontale du tube radiant. 3. Les fournaises doivent être aérées selon les recommanda- tions du fabricant. F-13 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 42 III. a) Quatre conduites de fumées de DE de 10 cm (4 po) sont requises. Une longueur maximale de 9,1 m (30 pi) est recommandée. F-14 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 43: Vue Latérale

    D = 10" (25.4 cm) D = 10" (25.4 cm) D = 8" (20.5 cm) ERSP-175 D = 10" (25.4 cm) D = 10" (25.4 cm) D = 8" (20.5 cm) F-15 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 44 Bague d'espace libre de Bague d'espace libre de 2"(5cm) Clearance thimble 5 cm (2 po) requise 5 cm (2 po) lorsque la conduite se prolonge dans des matériaux combustibles F-16 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 45: Conduite De Gaz

    1/2" Stainless Steel Flex Gas Connector 12,7 mm (1/2 po) Stk. #16401 Stock No 16401 45° Mouvement de la fournaise Heater Movement Heater Movement 45° Mouvement de la fournaise 90° MAUVAIS MAUVAIS F-17 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 46: Installation Électrique

    Igniter Wire Is 16 AWG / 25 KVDC / 10 KVDC All Quick Connects Are Fully Insulated (Except Igniter) Crimp Caps Are # CE5 / 105 Degrees C F-18 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 47: Haute Altitude

    ATTENTION : Avant d’ouvrir la porte jusqu'à 610 m (2000 pi) au-dessus du niveau de la mer. Au-dessus du brûleur du Heatstar ERSP® XL pour de 610 m (2 000 pi), un ensemble de conversion haute altitude peut procéder à un entretien ou une réparation, être nécessaire pour assurer les performances du brûleur.
  • Página 48 La vanne sera immédiatement désactivée et le ventilateur de combustion sera désactivé après la période de post- purge en option. F-20 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 49 Si un problème existe toujours, contacter le service à la clientèle des la flamme ne fonctionne pas correctement. Effectuez la produits techniques Heatstar, Inc au 1 866-447-2194 série suivante de vérifications pour corriger le problème. F-21 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 50 Parts List for Ener-Radiant SP Tube Heaters ERSP-40 Item Stock # Description Item Stock# Description F102594XL ERSP-40 NG / BRN et 02753 Rebord avant Boîte F102595XL ERSP-40 LP / BRN et 00419 Embout du réflecteur Boîte F106408XL Ensemble de tube de 3,0 m (10 pi) 09369 Pinces à...
  • Página 51 Tube H.E. DE 10 cm (4 po) x 3 m (10 00419 Embout du réflecteur 00418A Réflecteur 09369 Pinces à ressort 03447 Déflecteur de turbulateur de 1.5 m (10 pi) 14585P Support F-23 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 52 Embout du réflecteur Boît F106407XL Ensemble de tube de 15.2 m (50 pi) 09369 Pinces à ressort 06413 Tube H.E. DE 10 cm (4 po) x 3 m (10 F-24 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 53 1 1739 NG TO LP ERSP-150 1 1740 LP TO NG 1 1741 NG TO LP ERSP175 1 1730 LP TO NG 1 1731 NG TO LP F-25 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 54 125K LP ORIFICE 05503XL 150K PLAQUE D'AIR 07376 MOTEUR DE LA SOUFFLANTE 05796 150 NG ORIFICE 05728 150 LP ORIFICE 05508XL 175K PLAQUE D'AIR 05794 40K NG ORIFICE F-26 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 55 REMARQUES : F-27 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 56 Enerco Group, Inc se réserve le droit de modifier en tout temps, sans préavis ni obligation, les couleurs, spécifications, accessoires, matériaux et modèles. Enerco Group, Inc, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 866-447-2194 © 2021, Enerco Group, Inc Tous droits réservés F-28 Enerco | Heatstar ERSP Series Chauffe- INSTRUCTIONS D'UTILISATION ET MANUEL DU PROPRIÉTAIRE...
  • Página 57: Lea Cuidadosamente Las Instrucciones

    INSTRUCCIONES DE USO Y Modelo # ERSP-40 ERSP-60 ERSP-80 ERSP-100 MANUAL DEL USUARIO ERSP-125 ERSP-150 ERSP-175 LEA CUIDADOSAMENTE LAS INSTRUCCIONES: SU SEGURIDAD ES IMPORTANTE PARA USTED Y PARA LOS DEMÁS Lea y siga todas las instrucciones. Conserve estas instrucciones en un lugar seguro para futura referencia. No permita que nadie que no haya leído estas instrucciones arme, encienda, ajuste o use el calentador.
  • Página 58: Advertencia General De Peligro

    Enerco Group, Inc por recomendaciones. Sección 7 CABLEADO..............18 La instalación de los calefactores Heatstar ERSP se basa en Sección 8 OPERACIÓN Y MANTENIMIENTO...........18 la información suministrada en un diagrama de distribución, que junto con las normas y reglamentaciones mencionadas Sección 9 RESOLUCIÓN DE PROBLEMAS………………...………………21...
  • Página 59: Normas Nacionales Y Reglamentaciones Correspondientes

    Consideraciones críticas materiales, lesiones o la muerte. Normas nacionales y reglamentaciones El Heatstar ERSP es un calefactor suspendido. Por lo tanto, su correspondientes estabilidad, flexibilidad y seguridad son muy importantes. Antes de comenzar con la instalación, verifique que el sistema pueda Normas de gas: cumplir con los siguientes requisitos.
  • Página 60: Distancia A Combustibles

    La TABLA 1 indica las distancias mínimas aceptables a materiales combustibles. Las distancias indicadas en la TABLA 1 no se pueden usar en lugares cerrados por los cuatro costados. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario...
  • Página 61: Distancias A Combustibles Figura

    U-TUBE OPPOSITE 45 DEGREE U-TUBE STANDARD Tubo U estándar Tubo U, opuesto 45° Tubo U, completo 45° FRONT AND BACK CLEARANCE U-TUBE FULL 45 Separación adelante y atrás Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario...
  • Página 62: Caja Del Quemador

    TUBO DE 10' DEL INTERCAMBIADOR DE CALOR (06413) DEFLECTOR DE TURBULENCIAS 10' (03445) DEFLECTOR DE TURBULENCIAS DE 5' (03447) **NO VIENE INCLUIDO PARA TODOS LOS MODELOS** **ONLY HEATERS 30' LENGTH AND UNDER** Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario...
  • Página 63: Procedimiento De Instalación

    "apuntar" en la misma dirección. Adaptador de venteo Se usa para acoplar la tubería del intercambiador de calor a la tubería de venteo. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario...
  • Página 64 FIGURA 2A: Ener-Radiant SP Model ERSP-40 Intercambiador de 10' de largo. El largo total del calefactor es 11' - 4". 2 puntos de suspensión como se indica. GANCHO GANCHO 18” 18” 10' 2½" (3.1 1m) ALUMINIZADO ALUMINIZADO 9' Long Turbulator Section (1) SECCIÓN DE GENERADOR DE TURBULENCIA (9')
  • Página 65 10' 2½" (3.11m) 10' 2½" (3.1 1m) 10' 2½" (3.11m) 10' 2½" (3.1 1m) 10' 2½" (3.1 1m) 10' 2½" (3.11m) ALUMINIZADO ALUMINIZADO ALUMINIZADO ALUMINIZADO ALUMINIZADO ALUMINIZADO Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario...
  • Página 66 50 pi (15.25 m) Ninguno 61 pies 4 pulgadas (18.69 m) 15 pi (4.57 m) - 25 pi (7.62 m) ERSP-175 175,000 60 pi (18.3 m) Ninguno Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-10...
  • Página 67: Mecanismo De Acople

    180°. 18" (45cm) ACOPLE DE TUBERÍA 10" (25cm) (43cm) Acople (sin encastre) - 14612 Encastre para el acople - 14616 U-Tube Fitting Dimensions 180° U-Tube Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-11...
  • Página 68 3) Cuando los (3) tornillos de instalación estén ajustados, gírelos 1/4 de vuelta adicional para asegurar el tubo en el lugar. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-12...
  • Página 69: Especificaciones De Ingeniería

    3. Los calefactores deben ventearse de acuerdo con las recomendaciones del fabricante. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-13...
  • Página 70: Longitudes Del Venteo

    General Electric RTV106 o Permatex Form-A- ERSP-175 D = 10" (25.4 cm) D = 10" (25.4 cm) D = 8" (20.5 cm) Gasket Red High Temperature Silicone Adhesive Sealant. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-14...
  • Página 71: Ventilación Común Vertical

    Caja del quemador Burner Box Burner Box Burner Box Caja del quemador Burner Box 4” Aluminized steel Heat Exchange Tube 4” Aluminized steel Heat Exchange Tube Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-15...
  • Página 72 Terminación de extremo para pared simple 18"(45cm) 18" (45cm) Min. 3'-0" (91cm) Min. 6' (182cm) Min. 2"(5cm) Clearance thimble 2"(5cm) Clearance thimble required when flu pipe extends through combustible materials Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-16...
  • Página 73: Importante

    Conector flexible de acero inoxidable para gas de 1/2" Parte #16401 45° Movimiento del calefactor 45° Heater Movement Heater Movement Movimiento del calefactor 90° INCORRECTO INCORRECTO Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-17...
  • Página 74 Igniter Wire Is 16 AWG / 25 KVDC / 10 KVDC All Quick Connects Are Fully Insulated (Except Igniter) Crimp Caps Are # CE5 / 105 Degrees C Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-18...
  • Página 75: Mantenimiento

    Manténgase Lit:cableado interno Lit: Examine el quemador para cables invertidos. Comprobar el aislamiento en el encendedor conduce. Vuelva a colocar el módulo en caso necesario. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-19...
  • Página 76: Falla De Flujo De Aire

    La válvula se apagará inmediatamente, y el ventilador de combustión se apagará después del período opcional de purga posterior. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-20...
  • Página 77 Reemplazar el sensor. sensor de llama no funciona correctamente. Realizar las siguientes pruebas para solucionar Si persiste el problema, llamar al Servicio al cliente de Heatstar, Inc el problema. Technical Products al 1-866-447-2194 Enerco | Calefactor Heatstar ERSP Serie Tubor...
  • Página 78 Encastre para el acople de tubería 00419 Tapa del extremo del reflector 00419 Tapa del extremo del reflector 09369 Ganchos a resorte 09369 Ganchos a resorte Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-22...
  • Página 79 4" D.E.. X 10' 00419 Tapa del extremo del reflector Tubo de I.C. 00418A Reflector 09369 Ganchos a resorte 03447 Deflector de turbulencias de 14585P Soporte Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-23...
  • Página 80 Tapa del extremo del reflector Quemador y caja de control F106407XL - 50' 09369 Ganchos a resorte conjunto de tubo 06413 4" D.E.. X 10' Tubo de I.C. Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-24...
  • Página 81 NG TO LP ERSP-150 1 1740 LP TO NG 1 1741 NG TO LP ERSP175 1 1730 LP TO NG 1 1731 NG TO LP Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-25...
  • Página 82 150K PLACA DE AIRE 05796 150 NG ORIFICIO PRESIÓN 05728 150 LP ORIFICIO 05508XL 175K PLACA DE AIRE 07376 MOTOR DE VENTILADOR 05794 40K NG ORIFICIO Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-26...
  • Página 83 NOTAS : Enerco | Calefactor Heatstar ERSP Serie Tubor Instrucciones de uso y manual del usuario S-27...
  • Página 84: Por Información Acerca De Reparaciones O Partes

    La compañía garantiza que este producto estará libre de imperfecciones materiales y de fabricación, bajo condiciones de uso normales y adecuadas de acuerdo con las instrucciones de la Heatstar Compañía, por un período de 10 años a partir de la fecha de entrega al comprador.

Este manual también es adecuado para:

Ersp-80Ersp-125Ersp-175Ersp-60Ersp-100Ersp-150

Tabla de contenido