Breath Sampling With The Funnel - Dräger Alcotest 7000 Instrucciones De Uso

Ocultar thumbs Ver también para Alcotest 7000:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

en
|
Use
To take a passive breath sample:
1. Hold the ready device without the mouthpiece in the air to be
analyzed.
2. Briefly press the
 If alcohol is detected, the message ALCOHOL is displayed
and the red LED lights up.
 If no alcohol is detected, the message NO ALC. is displayed
and the green LED lights up.
 In the results display, PASSIVE is also displayed.
4.6.4 Low-volume breath sample (optional)
If the subject cannot provide the required minimum volume of breath,
a sample with a low volume can be taken. To take a breath sample
with a low volume, this option must be activated in the device menu.
When a breath sample is taken, the device checks whether this option
is activated. When the option is active, the device may take an early
breath sample and display Low volume next to the result.
4.7

Breath sampling with the funnel

4.7.1 Taking a breath sample
CAUTION
Hygiene
► Do not touch the upper part of the funnel.
► Always maintain a distance of 2–3 cm from the subject or object to
be tested.
► Do not touch excretions, surfaces or a subject's skin with the
funnel.
► Avoid direct contact with substances to be tested.
► Replace contaminated funnels.
16
button to start the measurement.
Dräger Alcotest
®
7000

Publicidad

Capítulos

Tabla de contenido
loading