Off Timer - Bang & Olufsen BeoVision 5 - 42 US Manual

Tabla de contenido

Publicidad

Plasma Display Panel (PDP) self-check
The self-check checks the status of the circuits connected to the IIC bus
➢1
LED
B
- Please refer to illustrations for:
- Placement of black self-adhesive tape on the PDP.
- Placement of buttons on NN Remote Control.
- Remove front frame and front cloth.
See illustrations, page 6.33.
- Remove the black self-adhesive tape on the Plasma Display Panel. See ➢1.
- Switch on the product.
- Enter Self-check mode.
Press button "B" on the Plasma Display Panel and at the same time button
OFF TIMER on the remote control. See ➢1 and ➢2.
The display will show ":-", while the self-check is performed.
- Result of self-check. See ➢3.
"OK"
No fault
"- -"
Fault in or missing circuit
- Exit Self-check mode.
Press Standby on NN Remote Control and thereafter press Standby on Beo4.
- Mount the black self-adhesive tape on the Plasma Display Panel.
- Mount the front cloth and front frame.
➢2
+
VOL
_
+
R
Standby
Plasma Dispay Panel self-check, English
➢3
ID
IIC1
D1
IC9355
IC9357
IC9007
IC9200
IC3001
IC3004
Z
IC2401

OFF TIMER

IIC2
IIC3
D2
OK H21
IC9900
OK H55
OK H51
IC9602
OK H55
OK H57
OK H52
IC9652
OK H53
H
IC3501
OK H56
OK H53
IC3699
OK H59
OK H54
IC3804
OK H60
IC4502
- - -
OK H58
6.11

Publicidad

Tabla de contenido
loading

Productos relacionados para Bang & Olufsen BeoVision 5 - 42 US

Este manual también es adecuado para:

8489

Tabla de contenido