Bang & Olufsen BeoVision 5 - 42 US Manual página 75

Tabla de contenido

Publicidad

6.14
Test, adjustment and confi guration after repair, English
Test, adjustment and confi guration after repair
WARNING
Test and adjustment
Confi gure PDP for B&O menu
Confi gure PDP for B&O menu
"Test and adjustment after replacement of module(s)"
Burn-in on the PDP might occur when displaying a non-moving picture for more
than app. 30 minutes.
"Test and adjustment after replacement of module(s)" must be executed after any
repair on the PDP.
The D1/D2 module must be confi gured to work with Bang & Olufsen features.
1. Please refer to illustration for:
- placement of buttons on Plasma panel and NN remote control.
- CAT Panel menu & CD mode.
2. Remove the front cloth, see page 6.33.
3. Remove the black self-adhesive tape.
4. Switch BV5 on.
5. Switch Plasma panel on.
Press the button marked A.
The Plasma led lights green.
6. Enter Service mode.
Press and hold the button B and at the same time press button C 3 times within 1
seconds.
7. Access to CD Mode in the CAT Panel menu.
Use the arrow buttons to select CD Mode.
Press the button D for 5 seconds.
8. CD menu
9. Check Memory Address and Data in Memory data change.
Use the arrow buttons to fi nd the required memory address in Memory data change.
First address code is set using the left/right arrow buttons.
Second address code is set using the up/down arrow buttons.
10. Check the Address and Data.
Address
0
Data
10
11. Change data in Memory data change.
Use the volume buttons (+/-) to change the Data value.
Change the data to the values below.
Data for Plasma Panel
Address
0
Data
10
8A
0
8C
10
01
10
8A
0
8C
10
01
10
0
8D
1A
1A
0
8D
1A
1A

Publicidad

Tabla de contenido
loading

Productos relacionados para Bang & Olufsen BeoVision 5 - 42 US

Este manual también es adecuado para:

8489

Tabla de contenido