Operation E; Battery / Charger F - Rothenberger ROMAX 3000 Instrucciones De Uso

Ocultar thumbs Ver también para ROMAX 3000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
3.7
Operation
Use only system-compatible press fittings and press jaws designed for them. The nominal size
of the press jaw must be identical with the nominal size of the press fitting.
When inserting the pipe / press fitting system, there is a risk of crush injuries for the
fingers or other body parts near the press jaw!
Press lightly the ON button to light up, white LED's lights up for 30 sec.
 Push the press fitting on to the pipe (1). Pull the press jaw apart and insert the pipe with the
press fitting at right angles.
There must be no foreign bodies between the press contour and the fitting. If you fail to
ensure this, the pressing process will not produce a perfect joint!
 Press the ON button until the pressing process has been completed (2). The motor cut out
indicates the end of the moulding cycle.
 Push the press jaw apart and take the machine off the joint (3).
Do not start the machine while the piston retracts or the emergency shutdown is pressed!
3.8
Battery / Charger
Power connection:
Connect only to single-phase a.c. current and only to the system voltage indicated on the rating
plate. It is also possible to connect to sockets without ground, as the design conforms to safety
class II.
Charging the battery:
ATTENTION! Overvoltage can damage or destroy the batteries and charger.
Always observe correct voltage!
The lithium-ion battery can be charged at any charging level and charging can be interrupted at
any time without damaging the battery (no memory effect).
 Insert plug of the battery charger into a wall socket: Red and green LEDs are lit.
 Connect the battery (1) to the battery charger (2): Charging control light (3) flashes green:
Battery is charged. Charging control light (3) is lit green: Battery is fully charged. (For charg-
ing time, see Technical Data).
 Keep button pressed and remove the battery.
 Disconnect plug from the wall socket.
Storage:
The place of storage must be inaccessible to children.
 Keep button pressed and remove the battery.
 Disconnect plug from the wall socket.
 Store battery charger in a dry, frost-proof location.
Store the battery only in a charged state! Fully recharge the battery after 12 months of stor-
age, at the latest!
Troubleshooting:
Before evaluating faults, disconnect the plug!
- Fault lamp (4) is lit red: Battery temperature outside the permissible charging temperature
(5°C to 45°C / 41°F-113°F).
- Fault light (4) flashes red: Battery is defective.
If the battery temperature is between 5°C and 45°C (41°F-113°F) and the red fault light (4) is
nevertheless lit, there may be a faulty contact.
- Clean contact points on battery.
In the event of other faults, please contact ROTHENBERGER Service. Repairs should only be
carried out by ROTHENBERGER service centres or dealers authorised by ROTHENBERGER.
ENGLISH