Componenti e apparecchiature sotto tensione non devono
essere accessibili a chi è immerso nella vasca.
3
0,6 m
2
3
1
0
0,6 m
2
Le vasche idromassaggio Jacuzzi® sono provviste di
morsetto, posto nelle vicinanze della pompa e contrad-
distinto dal simbolo , per il collegamento equipoten-
ziale delle masse metalliche circostanti, come previsto
dalle norme EN 60335.2.60.
ATTENZIONE! Scollegare l'apparecchiatura dalla linea
di alimentazione elettrica prima di effettuare qualsiasi
intervento di manutenzione.
Important
n
Please ensure that you thoroughly check the product
upon receipt since we cannot accept responsibility for any
damage reported after installation. Should you find any da-
mage, please immediately notify the forwarder.
n
Check that the arrangements comply with the instruc-
tions included in the present manual.
n
Check for any damage or defects by removing the protec-
tive plastic film (damages from impact or scratches reported
after installation are not covered by our guarantee).
n
Check that the clamps holding the rubber couplings and
the air lines are tightly fastened.
n
The installation of the whirlpool baths can be made
against finished (tiled) walls and floor.
The panels allow access to electromechanical devices instal-
led under the bath rim, as well as proper aeration required
for water-air mixture during hydromassage.
Aeration must be guaranteed also if Jacuzzi® panels are not
used (see "Instruction for pre-installation"). Panels must be
firmly installed and proper tools must be used when being
removed. Openings, holes, grids, used for aeration, should
not allow the introduction of objects having a diameter of
12 mm or larger.
1
3
0
0,6 m
CAUTION: (IEC 60335-1/A2) The pressure of the water
system supplying water to the appliance must not ex-
ceed 600 kPa (6 bar).
Where a distribution drainage column is present, a DB
type protective unit must be installed (Standard EN
1717), placed at least 15 cm above the tub edge. Con-
tact the Supplier Company and/or the hydraulics engi-
neer to determine the type of system required.
EN 1717
DB
Electrical safety
Jacuzzi®" hydromassage products are safe appliances, manufac-
tured according to EN 60335.2.60, EN 55014 and EN 55014-2.
They are tested during production to guarantee user safety.
Installation must be carried out by qualified and authorized per-
sonnel, in compliance with current national provisions.
It is the responsibility of the installer to select proper
materials, carry out the work correctly and check the
condition of the system to which the unit will be con-
nected and the unit itself in order to ensure user safety.
Jacuzzi® whirlpool baths are Class "1" appliances and thus must
be securely anchored and permanently connected to the electric
mains and earth system without any intermediate connections.
The electrical system and earth system of the building
must be in working order and must comply with the le-
gal provisions and specific regulations in force in the
country of use.
An appropriate device must be provided, as part of the
fixture and installed in compliance with current regu-
lations, which disconnects the equipment from the
mains.
For connection to the mains, it is necessary to install a discon-
necting multiple-pole switch that provides full disconnection
under overvoltage category III conditions and place it in an area
that complies with the safety prescriptions for bathrooms.
5 5