Parker Hiross Hyperchill-Plus ICEP040 Manual De Uso página 151

Ocultar thumbs Ver también para Hyperchill-Plus ICEP040:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
7.3 Techincal data
MODBUS
unit adress
BaudRate
9600
Protocol Parity
Address Display label App type Default
8964
Set
INT
13(55,4)
8965
dIF1
INT
4(7,2)
8966
dIF2
INT
0,3(0,5)
8969
OFFC
INT
2(3,6)
8970
ONC
INT
1(1,8)
8973
LiS
INT
5(41)
8974
HA1
INT
60(140)
8975
LA1
INT
-40(-40)
8976
db1
INT
1(1,8)
8977
HA2
INT
60(140)
8978
LA2
INT
2,5(36,5)
8979
dI2
INT
4(7,2)
8980
HA3
INT
60(140)
8981
LA3
INT
-30(-22)
8982
SEA
INT
19(66,2)
8983
dIA
INT
1(1,8)
8984
ArA
INT
5(41)
8985
DtHA
INT
5(9)
8986
SRQH
INT
30(86)
8987
drq
INT
19(34,2)
8988
SrC
INT
15(59)
8989
drC
INT
2(36)
8990
SRQL
INT
5(41)
8995
PStA
INT
0
8996
SUP
BOOL
FALSE
16385
rE
USINT
0
16387
SUP
BOOL
FALSE(0)
16384
C-F
BOOL
FALSE(0)
16386
rAL
USINT
0
16388
Ud4E
BOOL
FALSE(0)
16390
ASt
BOOL
TRUE(1)
16391
r0n
UINT
6
16465
CPT
BOOL
FALSE(0)
16445
Erd
BOOL
FALSE(0)
8999
Dma
INT
25(77)
8961
dMin
INT
15(59)
16423
dAS
USINT
5
16431
tH1
INT
0
16472
tH1L
INT
0
16409
CHA1
BOOL
TRUE(1)
16414
CHA2
BOOL
TRUE(1)
16411
CLA1
BOOL
FALSE(0)
16419
rLa
USINT
5
16420
tLa
USINT
60
16432
AbPd
BOOL
TRUE(1)
16433
dPOn
USINT
15
1
EVEN
NONE
1
ODD
Min
Max
Unit
LIS
65(149)
°C/(°F)
0,3(0,5)
10(18)
°C/(°F)
0,3(0,5)
10(18)
°C/(°F)
ONC
10(18)
°C/(°F)
0(0)
OFFC
°C/(°F)
LA2
65(149)
°C/(°F)
-40(-40)
65(149)
°C/(°F)
-40(-40)
65(149)
°C/(°F)
1(1,8)
10(18)
°C/(°F)
-40(-40)
65(149)
°C/(°F)
-40(-40)
65(149)
°C/(°F)
1(1,8)
10(18)
°C/(°F)
-40(-40)
65(149)
°C/(°F)
-30(-22)
65(149)
°C/(°F)
LIS
65(149)
°C/(°F)
1(1,8)
10(18)
°C/(°F)
-30(-22)
65(149)
°C/(°F)
0(0)
30(54)
°C/(°F)
-10(14)
55(131)
°C/(°F)
0(0)
30(54)
°C/(°F)
-30(-22)
50(122)
°C/(°F)
0(0)
10(18)
°C/(°F)
-10(14)
30(86)
°C/(°F)
0
1
FALSE
TRUE
0
2
FALSE(0)
TRUE(1)
FALSE(0)
TRUE(1)
0
2
FALSE(0)
TRUE(1)
FALSE(0)
TRUE(1)
0
300
sec
FALSE(0)
TRUE(1)
FALSE(0)
TRUE(1)
0(32)
37(98,6)
°C/(°F)
-20(-40)
37(98,6)
°C/(°F)
0
10
Minutes
0
9999
KHours
0
9999
Hours
FALSE(0)
TRUE(1)
FALSE(0)
TRUE(1)
FALSE(0)
TRUE(1)
0
15
5
60
Minutes
FALSE(0)
TRUE(1)
dLE
60
Sec
ICEP040-060
Not configurable
Stop Bit
Data Bit
Address with offset 40000 (es: 8964+40000=48964)
Read Only
Note
FALSE
Set point
FALSE
Differential 1 for thermostating
FALSE
Differential 2 for thermostating
FALSE
Differential for compressor OFF
FALSE
Dirrerential for compressor ON
FALSE
Set point lower limit
FALSE
B1 High terperature alarm
FALSE
B1 Low temperature alarm
FALSE
B1 Low level temperature alarm retrigger
FALSE
B2 High temperature alarm
FALSE
B2 Low temperature alarm
FALSE
B2 Alarm differential
FALSE
B3High temperature alarm
FALSE
B3 Low temperature alarm
FALSE
Set point (B1) antifreeze
FALSE
Thermostating differential (B1)
FALSE
Set point activation (B3)
FALSE
Differential for dipendent water exit regulation
FALSE
SetH point for control panel heater
FALSE
Differential control panel heater
FALSE
Setpoint Carter Heater
FALSE
Differential value for carter heater
FALSE
SetL point for control panel resistor
TRUE
Status ON/OFF dryer
FALSE
Supervisor ON OFF request (to change the state machine - change True from "0" to "1")
FALSE
Remote ON/OFF enable
FALSE
ON/OFF enable from supervison
FALSE
Unit of measure (FALSE=°C, TRUE=°F)
FALSE
Alarm relè management
FALSE
Enable antifreeze resistor 0=disabled
FALSE
Autostart enable 0=NO 1=YES
FALSE
Main power supply return
FALSE
CPT control 1=Enable
FALSE
Enable managing water with Ambient temperature
FALSE
Max value to stop compressor in ERD
FALSE
Min value to run compressor in ERD
FALSE
Minimun time between two switch ON of the same compressor (minutes)
FALSE
Compressor 1 working hours warning threshold (x1000)
FALSE
Compressor 1 working hours warning threshold
FALSE
HA1 alarm management
FALSE
HA2 alarm management 0=Warning; 1=Alarm; 2=System
FALSE
LA1 alarm management
FALSE
Max number of Events LA2 Alarm
FALSE
Interval Time LA2 Alarm
FALSE
Enable delay switching on pump
FALSE
Delay switching ON pump (sec) at power on
10

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hyperchill-plus icep050Hyperchill-plus icep060

Tabla de contenido