Set the High Temperature Limit
Stop (optional)
Lift the handle (1).
Use a 4 mm �llen wrench to push the screw cover
into the handle ().
Use the 4mm �llen wrench to loosen the handle
screw 4 complete revolutions (3).
Remove the handle (4).
Retrieve the screw cover.
Remove the nut cover.
Turn the stem counter-clockwise.
Remove the handle screw (1).
Remove the high temperature limit stop ().
Replace the high temperature limit stop so that the pin
on the cartridge is in the desired slot on the limit stop.
Note: the temperatures given in the diagram as-
sume a water heater temperature of 140° F, a cold
water temperature of 50°F and a water pressure of
45 PSI.
Replace the nut cover (1).
Replace the handle screw. Use the �llen wrench to
turn the screw 4 revolutions ().
Replace the handle (1). Tighten the handle screw ().
Install the screw cover (3).
1