Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
6. LIMIT SWITCH ADJUSTMENT
6.1. To install and adjust the limit switches in opening procede as
follows (Fig. 12):
- Completely open the gate.
- Place the plate on the rack in order to have the lever of the
mechanical limit switch (Fig. 13) in correspondance of the limit
sheet and fix it with the delivered screws (Fig. 14).
6.2. To install and adjust the limit switches in closing the gate
must be completely closed.
Limit switch in closing
Mechanical limit switch
Setting the trimmer for braking on the electronic control unit, it is
possible to make the gate stop on the desired position.
67411230
®
Fig. 12
Limit switch in opening
Fig. 13
Fig. 14
7. MAGNETIC LIMIT SWITCH
Fig.15
Fig.16
Sliding gate
Magnet
Limit sheet
Rack
Pinion
Fig.17
Verify the correct reading of the limit switches before starting the
selflearning of the times on the unit.
Fig.18
ENGLISH
Steel rack
Plastic rack
MAX 10 mm
11