BTL7-S5 _ _ ( _ )-M _ _ _ _ -A/B/Y/Z(8)-S32/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The BTL magnetostrictive linear position sensor, together
with a machine controller (e.g. PLC), comprises a position
measuring system. It is intended to be installed into a
machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty.
Opening the BTL or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation and startup may only be performed by
qualified personnel.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the BTL will not result
in hazards to persons or equipment.
If defects and unresolvable faults occur in the BTL, it
should be taken out of service and secured against
unauthorized use.
Downloading further instructions
A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
BTL7...cable
Ø max. 7
BTL7...-S32
13.5
11
3)
Unusable area
4)
Not included in scope of delivery
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
1
english
Mounting surface
B: 30-1 mm
Z: 2"-0.04"
3)
Magnet
Thread size
0.5 Ø 25
B: M18×1.5
Z: 3/4"-16UNF
71
25
Mounting surface
G
Thread M4x4/
6 deep
No thread
Dimensions and function
The BTL contains the waveguide which is protected by an
outer stainless steel tube (rod). A magnet is moved along
the waveguide. This magnet is connected to the system
part whose position is to be determined.
LED 1
Operating state
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Operating state
Green
Synchronous operation 2)
Internal measurement is synchronous to
SSI query.
Off
Asynchronous operation 2)
Internal measurement is asynchronous to
SSI query.
Flashing
Programming mode
green
Only with BTL7-S510...
1) Not for BTL7-...-FA_ _
2) Asynchronous operation is reached when the external sampling rate is
> f
or < 62.5 Hz (only with BTL7-S5_ _B/F-...).
A,max
Damping zone
60
Nominal length =
Measuring range
4)
A: 30-1 mm
Y: 2"-0.04"
4)
3)
Thread size
25
71
A: M18x1.5
Y: 3/4"-16UNF
1)
3)
LED 1
LED 2
45
46