Technical Data Table; Installation; Laws, Technical Rules And Norms - Lotus CW-74ET Guia Para La Intalación E Instrucciones De Uso

Parrilla electrica para uso profesional
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

MODELS
DIMENSIONS
cm
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
POWER SUPPLY
MAXIMUM ABSORPTION
MAXIMUM POWER
POWER SUPPLY CABLE
(Silicone)
The data plate is on the side of the appliance (see figure 1) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessibile.
It is advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed
near walls, dividing panels, kitchen furniture, decorative finishings, etc. , these should be in flameproof material;
otherwise it is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
Attention! This appliance has been produced for use as part of a battery. If used singly, it will be necessary to keep it at
least 10cm away from the adjacent walls.
Installation must be carried out observing the following norms:
- Safety prescription in force
- Installation prescription, ECI norms.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or
installation which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it; this device must have a contacts opening of at
least 3 mm.
GB

TECHNICAL DATA TABLE

CW-74ET
CWT-74ET
40x70x90 h
400VAC/3N 50/60 Hz 400VAC/3N 50/60 Hz 400VAC/3N 50/60 Hz 400VAC/3N 50/60 Hz
8,75 A
6 KW
5x1 mm²
TRANSFORMATION
230Vac3 50/60 Hz
230Vac3 50/60 Hz
15,06 A
6 KW
4x1,5 mm²
INSTRUCTIONS FOR INSTALLATION

INSTALLATION

LAWS, TECHNICAL RULES AND NORMS

IE
CW-78ET
40x70x29 h
80x70x90 h
8,75 A
17,5 A
6 KW
12 KW
5x1 mm²
5x2,5 mm²
230Vac3 50/60 Hz
15,06 A
30,12 A
6 KW
12 KW
4x1,5 mm²
4x4 mm²
18
CWT-78ET
80x70x29 h
17,5 A
12 KW
5x2,5 mm²
230Vac3 50/60 Hz
30,12 A
12 KW
4x4 mm²

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cwt-74etCw-78etCwt-78et