Extensions
If an extension cable is used, make sure it is fit for the power
draw and protection degree of the vacuum cleaner.
Minimum section of extension cable L = 20 m max.
Max power (kW)
3
Minimum section
2.5
(mm
)
2
DANGER !
Sockets, plugs, connectors and installation of the
extension cable must maintain the IP protection degree
of the vacuum cleaner, as indicated on the data plate.
DANGER !
The vacuum cleaner power socket must be protected
by a differential circuit-breaker with surge current
limitation, that shuts off the power supply when the
current discharged to the ground exceeds 30 mA for 30
msec. or an equivalent protection circuit.
DANGER !
Never spray water on the vacuum cleaner: such action
constitutes a danger hazard for persons and could short
circuit the power supply.
Consult the latest edition of the European Union
Directives, the Laws in the country of use and the
current Standard References in force (UNI - CEI - EN),
particularly the EN 60335-2-69 European Standard
Reference.
5
15
22
4
10
16
-5-
125/BDC1216/BDC1324/CV324/135/E-VAC1000
Dry applications
Note
The supplied filter must be correctly installed.
Maintenance and repairs
DANGER !
Disconnect the vacuum cleaner from its power source
before cleaning, servicing or replacing parts; the plug
must be removed from the socket.
DANGER !
-
Carry out only the maintenance operations
described in this manual.
-
Use only original spare parts.
-
Do not modify the vacuum cleaner in any way.
-
Failure to comply with these instructions could
jeopardize your safety. Moreover, such action would
immediately void the EC declaration of conformity
issued with the vacuum cleaner.
DANGER !
To carry out maintenance operations that are not
described in this manual, contact the manufacturer's
Service Centre or his sales network.