►►5. CONNECTION TO THE
MAINS ELECTRICITY
CHECK YOUR ELECTRIC SYSTEM IS
EARTHED CORRECTLY.
Before connecting the generator to the
mains electricity, make sure that the
power supply voltage and frequency are
correct (see data plate applied to the
generator). The connection to the mains
electricity (Fig. 10) must be made in
compliance with the National Standards
in force.
►►6. IGNITION FOR MANUAL
MODELS (... kW / ... kW R / ... kW
DV)
IMPORTANT: For ... kW DV models,
check the position of the transformer
switch (220-240V / 110-120V) (Fig. 11).
If the voltage set on the appliance does
not correspond to that supplied by the
mains, the voltage must be adapted.
Loosen the 2 lid screw fasteners (Fig.
12), shift the switch onto the voltage
value supplied (Fig. 13) and re-mount
the lid (Fig. 14).
● 6.1. HEATING MODE:
►6.1.1.Take the "O/I" switch to position
"I" (Fig. 15).
►6.1.2.Press the gas button fully home
and hold it down (Fig. 16).
►6.1.3.Activate the piezoelectric igniter
fully home and repeatedly (Fig. 17),
keeping the gas button pressed (Fig. 16).
►6.1.4.After ignition of the fl ame, hold
the gas button down for about 15 s (Fig.
18).
►6.1.5.Release the gas button (Fig. 19).
In the event of a power cut or if there is
no gas supply, the appliance will switch
off. The generator does not switch back
on automatically. It must be switched
on manually by repeating the switch-on
procedure.
If the appliance does not switch on,
consult the relative section (Par. 13.
"TROUBLESHOOTING").
● 6.2. VENTILATION MODE:
The generator can also be used as a
fan. Connect the generator to the mains
electricity (Fig. 10) and take the "O/I"
switch to position "I" (Fig. 15).
N.B.: With the generator functioning
in heating mode, before passing to
ventilation mode, carry out the correct
switch off sequence for the manual
models [Par. 9. "SWITCH-OFF FOR
MANUAL MODELS (... kW / ... kW R / ...
kW DV) " ].
►►7. IGNITION FOR
ELECTRONIC MODELS (... kW E)
►7.1.Take the "O/I" switch to position "I"
(Fig. 15).
►7.2.Press the "RESET" button (Fig.
20).
The
generator
sequence and the fl ame ignites after
about 20÷30 s (see functioning layout
Fig. 21).
In the event of a power cut or if there is
no gas supply, the appliance will switch
off. The generator does not switch back
on automatically. It must be switched on
manually by pressing the "RESET" button
(Fig. 20).
If the appliance does not switch on,
consult the relative section (Par. 13.
"TROUBLESHOOTING").
ATTENTION: If the generator stops
due to the intervention of the room
thermostat
(optional
appliance
will
automatically when the temperature
drops below the threshold set.
starts
the
analysis
article),
switch
back
IT
GB
DE
ES
FR
NL
PT
DK
FI
NO
SE
PL
RU
CZ
HU
SI
TR
HR
LT
LV
EE
RO
SK
BG
the
GR
on
CN

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Blp 14 kwBlp 15 kw rBlp 26 kwBlp 33 kwBlp 53 kwBlp 73 kw ... Mostrar todo

Tabla de contenido