DR560 Changing the Heating Element
To perform this operation, turn off the station or disconnect the tool.
1. Loosening
The deposit lid needs to be
loosened.
2. Removing
Loosen the screw as shown
and remove the
Heating Element.
3. Placing
Place the new Heating
Element and follow the steps
conversely.
3
Important
For a proper connection it is essential to insert the cartridge by lining it up to the mark
22
2
1
.
DR560 Tin Deposit Cleaning
1. Removing the lid
Check
internal joint
Check filter
Lid
The lid must be removed with the DR560 in
vertical position.
3. Inserting the deposit
The deposit must be inserted with coil filter in
place, positioned between the 2 lines marked
on the tin deposit.
Then the whole unit must be closed by
screwing the lid.
w w w.jbctools.com
2. Cleaning
Remove the coil to clean the inside of the
deposit with the stick supplied.
The filter and internal joint must be checked
and replaced if dirty or damaged.
Marks
23