Managing Power Amplifiers - LD Systems LDDSP44K Manual De Usuario

Ocultar thumbs Ver también para LDDSP44K:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 69

7. MANAGING POWER AMPLIFIERS

7.1
7.7
7.9
The LD OCS software provides the opportunity to manage multiple LD DSP44K and DSP45K power amps. Click with the right mouse button
on the desired amplifier to access the editing menu for power amps.
Ethernet Config - In the Ethernet Config editing window, you can view network information, change the IP address of the power amp,
7.1
enable DHCP if supported by the network, reset the power amp Ethernet module, assign a name to the power amp, and, with multiple
connected power amps, identify a specific one (not possible with USB connection).
7.2
Network Information - Shows network information.
IP Address - To manually change the IP address, disable DHCP (check the box), enter the address, and click Update IP/DHCP
7.3
To reset the Ethernet module of the power amp, click on Reset Ethernet Module.
Device Name - Enter a name into the input field (8 characters maximum) and click on Change Device Name.
7.4
7.5
Identify Device - To identify a power amp, click on Identify Device; this will display the
power amp name and IP address on the device display for a short time.
7.6
Reconnect Device - To recreate an interrupted connection (e.g. after a power outage), click on Reconnect Device.
Add Virtual Device - To check or recreate an amp preset offline, you can add a virtual power amp under "Amplifiers".
7.7
To do so, click on Add Virtual Device and select DSP44K from the LD series. This virtual power amp will be shown as "offline" under
series number.
7.8
Delete Device - To delete a power amp from the Amplifiers list, click on Delete Device.
Rename Device - Click on Rename Device, to rename the power amp, enter a name into the entry field that opens,
7.9
and click OK.
Identify Device - To identify a power amp, click on Identify Device; this will display the
7.10
power amp name and IP address on the device display for a short time (not possible for USB connection).
Click with the right mouse button on Amplifiers to access the editing menu.
Add Virtual Device - To check or recreate an amp preset offline, you can add a virtual power amp under "Amplifiers".
7.11
To do so, click on Add Virtual Device and select DSP44K from the LD series. This virtual power amp will be shown as "offline" under
series number.
7.12
Add new Zone - Adds new zone.
Delete selected Zone - Deletes selected zone.
7.13
7.14
Rename selected Zone - Renames selected zone.
7.1
7.2
7.6
7.8
7.3
7.10
7.4
7.5
7.11
7.12
7.13
7.14
.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lddsp45k

Tabla de contenido