INSTALLATION
a
WARNING!
• Danger of malfunction and breakdowns resul-
ting from short�circuits.
• Check the cable retainer is sufficiently tight to avoid undue
strain on the connections.
• Check that the cables are correctly secured and
connected.
• Replace the protective wiring cover.
11.5
Electrical characteristics
Fig. 11.3 Electrical layout for outdoor and indoor connection.
Legend
1
Connector strip for the outdoor unit
2
Connector strip for the indoor unit
Power supply (V/Ph/Hz)
Supply section up to 25 meter (in mm
Indoor / Outdoor
Thermal�magnetic circuit breaker, type D (A)
Interconnection section up to 25 meter (mm
Inteconnect shielded cable or not (YES/NO)
Immediatte residual current protector (A)
Table 11.1 Electrical Characteristics.
16
1
2
VAI 6-025 WN
230/1/50
)
1.5
2
Indoor
10
)
1.5
2
NO
0.03
VAI 6-035 WN
VAI 6-050 WN
230/1/50
230/1/50
1.5
1.5
Indoor
Indoor
10
16
1.5
1.5
NO
NO
0.03
0.03
VAI 6-065 WN
230/1/50
1.5
Indoor
20
1.5
NO
0.03