Flotec FPT20510 Manual Del Usuario página 8

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Electrical
Two Speed Motor
These pump motors require that input power be applied
to specific terminals to obtain low or high speed
operation.
• To connect the motor for low speed operation, attach
the input power leads to the L2 terminal (common)
and the A terminal (low speed) of the terminal board
located under the rear canopy.
Low Speed Operation
• To connect the motor for high speed operation,
attach the input power leads to the L2 terminal (com-
mon) and the L1 terminal (high speed) of the termi-
nal board located under the rear canopy.
High Speed Operation
For parts or assistance, call Flotec Customer Service at 1-800-365-6832.
A
L2
L2
L1
Wiring
Pump must be permanently connected to circuit. Table I
gives correct wire and circuit breaker sizes for the pump
alone. If other lights or appliances are also on the same
circuit, be sure to add their amp loads to pump amp load
before figuring wire and circuit breaker sizes. (If unsure
how to do this or if this is confusing, consult a licensed
electrician.) Use the load circuit breaker as the master
on-off switch.
Install a Ground Fault Circuit Interrupter (GFCI) in circuit;
it will sense a short-circuit to ground and disconnect
power before it becomes dangerous to pool users. For
size of GFCI required and test procedures, see GFCI
manufacturer's instruction.
In case of power outage, check GFCI for tripping (which
will prevent normal pump operation). Reset if necessary.
NOTICE If you do not use conduit when wiring motor,
be sure to seal wire opening on end of motor to prevent
dirt, bugs, etc., from entering.
Table I - Recommended Fusing Data
Branch
Max
Voltage/
Motor
Fuse Rating
Load
Hz/
HP
Amps*
Amps
Phase
1
6.1
15
230/60/1
1-1/2
7.7
* Time delay fuses are recommended instead of standard fuses in any motor circuit.
8
Service to Motor
Distance in Ft . (m)
0-100'
101-200'
201-300'
(0-30)
(30-60)
(60-90)
AWG Wire Size (mm²)
14(2)