gala gar GALA MIG 4100 Manual Técnico De Instrucciones página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

VOLTAGE CHANGE
All the equipment from the GALA INDUSTRIAL
series have two voltages (standard version at
230/400 V). Therefore it is necessary to check that
the voltage selected on the equipment coincides
with the mains voltage.
Fig. 3. Voltage change system.
2.2. INSTALLATION OF AUTO-COOLED MODULATE MIG SYSTEM (WITHOUT COOLING).
The wire-feed unit must be connected to the power source. Fig. 4 describes the installation process of GALA
INDUSTRIAL equipment without cooling.
The connection is made with the connection extension A (see table 4). The installation is comprised of the
following elements:
B-
CONTROL hose.
C-
Shielding GAS line.
D-
POSITIVE supply pole.
E-
Shielding gas hose.
F-
Pressure reducing valve.
G-
Welding torch.
H-
Earth taps.
M-
Welding earth clamp.
N-
Power supply hose
O-
Connection plug.
Fig. 4. Installation of GALA INDUSTRIAL equipment without cooling.
GALA INDUSTRIAL. Instructions Manual.
E, which is connected to the rear of the power source.
The gas flow can be controlled with the pressure
reducing valve F to a recommended value between 10
and 12 l/min. (wide range depending on wire)
letter H. We must place earth J to a tap, which will be
chosen depending on the thickness to be welded (see
section 3.1).
Standard equipment leaves the factory with the
voltage selected at 400 V.
voltage place screw T in position 2. To connect the
equipment move indicator to 230 V position.
DO NOT FORGET TO FIT THE EARTH
CONNECTION INTO THE PLUG.
MAKE SURE THE MAINS VOLTAGE
COINCIDES WITH
THAT ESTABLISHED IN THE MACHINE.
The gas bottle is joined to the system with conduit
The power source earth taps are designated with
21
To change to 230

Publicidad