Technical Data; Power Requirements - Truper PISCA-A-2 Manual De Instrucciones

Ocultar thumbs Ver también para PISCA-A-2:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Technical Data

Code
Description
Voltage
Frequency
Current
Power
Speed
Work Cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING

Power Requirements

WARNING
Tools with double insulation and reinforced insulation
eliminate the need of a grounded power cord with three prongs or a grounded
power connection.
WARNING
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in
the line, resulting in power loss and overheating. The following table
shows the right size to use depending on cable's length and the ampere
capability shown in the tool's nameplate. When in doubt use the next
higher gauge.
Ampere
Capacity
from 0 A and up to 11 A
from 11 A and up to 15 A
from 15 A and up to 17 A
from 17 A and up to 23 A
There is risk of fire if the tool is not used with care, so it is necessary to:
WARNNG
Be careful when using the tool in places where combustible materials are present. Do not apply in the same place for
prolonged periods. Do not use in the presence of explosive atmospheres. Keep in mind that some combustible materials can lead to heat
without this being evident in sight. Place the tool in its base after it is used and allow it to cool down before it is stored. Do not leave the tool
unattended when it is in operation.
30 minutes work per 15 minutes rest. Maximum 3 hours daily.
Number of
Conductors
3
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE-2006
PISCA-A-2
15734
Heat Gun
220 V
50 Hz / 60 Hz
9,1 A
2 000 W
11 000 RPM - 17000 RPM
H05VV-F x 2C with 221 °F insulating temperature.
Class II
Power cord grips type: Y
Build quality: Reinforced insulation.
Extension gauge
from 5.9' to 49.2' |
18 AWG( * )
16 AWG
14 AWG
10 AWG
Authorized Service Center.
higher than 49.2'
16 AWG
14 AWG
12 AWG
8 AWG
ENGLISH
3

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

15734

Tabla de contenido