OPERATION
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
outdoor use that are rated for the electrical load.
Minimum Gauge, Outdoor Rated
Total
Amperage
Up to 50 FT (15 M)
Up to 10A
12
10
Up to 15A
10
Up to 20A
8
Up to 30A
6
Up to 35A
ST SWITCH
The wGen9500DF is compatible with the ST Switch,
purchased separately. When utility power is on it will
provide power (up to 120V @ 20A) to the appliances
plugged into the 5-20R receptacle on the ST Switch. When
utility power is lost the ST Switch automatically transfers
input power from utility to generator power. When utility
power is restored, the ST Switch transfers input power
back to utility. Visit www.westinghouseoutdoorpower.com
for more information.
18 | Westinghouse Outdoor Power Equipment, LLC
Up to 100 FT (30 M)
1
8
8
1
6
6
6
TRANSPORTING
Weight hazard. Always have assistance when lifting the
generator.
• Allow the generator to cool a minimum of 30 minutes
before transporting.
• Replace all protective covers on the generator control
panel.
• Only use the generator's fixed frame to lift the unit or
attach any load restraints such as ropes or tie-down
straps. Do not attempt to lift or secure the generator by
holding onto any of its other components.
• Keep the unit level during transport to minimize the
possibility of fuel leakage or, if possible, drain the fuel
or run the engine until the fuel tank is empty before
transport.
• The generator wheels are only intended for hand
transport. The wheels are not suitable for towing the
generator either on or off-road.
• Use the extendable handle for one-person, hand
transport. Only use the handle while the generator is
OFF, stationary, and resting on a horizontal surface. Do
not use the handle to lift the generator entirely off the
ground, tow it, or up-end it.
Fire hazard. Do not up-end the generator or place it on
its side. Fuel or oil can leak and damage to the generator
may occur.
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
Maintenance Code Required Maintenace
P25
Change engine oil
P50
Change engine oil, clean air filter
P100
Change engine oil, clean air filter
CAUTION
CAUTION