5 ELECTRICAL CONNECTIONS
Execute the wiring following the directions of table 1 and diagrams on page 21.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm
in the open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure
multi pole disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1-2
230 V ~ ±10% (50/60 Hz) power supply input
3-4-5
Operator 1 output 230 V ~ max 600W
6-7-8
Operator 2 output 230 V ~ max 600W (if present)
9-10
230 V ~ max 100 W output for open gate warning light (if P052=0) or courtesy light (if P052>1)
11-12
Flashing light output 230 V ~ max 40W
13 (-)
13-14
14 (+)
15-16
Led flashing light output max 1 art. LED24AI (24 V
17
Input 6
18 - Com
19
Input 5
20 - Com
21
Input 4
22 - Com
23
Input 3
24 - Com
25
Input 2
26 - Com
27
Input 1
28 - Com
29
Aerial signal input
30
Ground aerial input
31-32
+24 V
20
Table 1 "terminal board connections"
Electric-lock output max 1 art. 110 (if P062=0), 24V
electro-brake output for reversible motors (if P062=3)
TYPE 00
TYPE 01
If unused, short circuit
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PED.)
N.C.
N.C.
( PHOTO 1)
(SAFETY)
N.C.
N.C.
(SAFETY)
(PHOTO 1)
N.C.
N.C.
(PED.)
(PHOTO 2)
N.O.
N.C.
(START)
(START)
N.O.
N.O.
power supply output for auxiliary devices 200mA
output max 5W configurable (if P062≠0) or
max 100 mA)
TYPE 02
TYPE 03
(NONE)
(NONE)
N.O.
N.O.
(NONE)
(NONE)
N.O.
N.O.
(STOP)
(NONE)
N.C.
N.O.
(SAFETY)
(NONE)
N.C.
N.O.
(PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(START)
(START)
N.O.
N.O.
.
2
TYPE 04