5 ELECTRICAL CONNECTIONS

Execute the wiring following the directions of table 1 and diagrams on page 23.
WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart (minimum 4mm
in the open or 1 mm through insulation) from low voltage cables (motors power supply, controls, electric locks, aerial and auxiliary
circuits power supply), and fasten the latter with appropriate clamps near the terminal boards.
WARNING Connect to the power supply 230 V ~± 10% 50 Hz through a multi pole switch or a different device that can ensure
multi pole disconnection from the power supply, with a contact opening of 3 mm.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,22mm
1-2
+24 V
3-4
22 V ~ transformer power supply input
24 V
5-6
indications).
7-8
Operator 1 output
9
Connection of motors metallic parts
10-11
Operator 2 output (if present)
12-13
24 V
14 (-)
14-15
15 (+)
16-17
24 V
18
Input 6
19 - Com
20
Input 5
21 - Com
22
Input 4
23 - Com
24
Input 3
25 - Com
26
Input 2
27 - Com
28
Input 1
29 - Com
30
Aerial signal input
31
Ground aerial input
32 (+)
32-33
33 (-)
Encoder selection Jumper:
J5
J9
•A position = operators with encoder (remind to set P029=0)
B
A
B
A
•B position = operators without encoder (remind to set P029=1)
22
Table 1 "terminal board connections"
power supply output for auxiliary devices 200mA
battery power supply or photovoltaic accumulator Green Energy input (follow carefully polarity
max 15 W output for open gate fix/flashing warning light (if P052=0/1) or courtesy light (if P052>1)
"Boost" output for electric-lock, max 1 x art. 110 (if P062=0), 24V pulse output, max 5W (if P062=1),
step by step (if P062=2), electro-brake output for not self-locking operators (if P062=3), output for
electric-lock power supply via external relay (if P062=4), output for electro-magnets power supply for
barriers (ifP062=5) or temporized output (if P062>5).
Flashing light output max 15W art. Lumy/24A/S
TYPE 00
TYPE 01
If unused, short circuit
(FCC 1)
(STOP)
N.C.
N.C.
(FCA 1)
(PHOTO 2)
N.C.
N.C.
( PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(SAFETY)
(SAFETY)
N.C.
N.C.
(PEDESTRIAN)
(PEDESTRIAN)
N.O.
N.O.
(START)
(START)
N.O.
N.O.
DE@NET mains input (unused at the moment)
.
2
TYPE 02
TYPE 03
(NONE)
(NONE)
N.O.
N.O.
(NONE)
(NONE)
N.O.
N.O.
(STOP)
(NONE)
N.C.
N.O.
(SAFETY)
(NONE)
N.C.
N.O.
(PHOTO 1)
(PHOTO 1)
N.C.
N.C.
(START)
(START)
N.O.
N.O.