EN
GENERAL
Your air compressor was designed for 100% continuous duty operation
with the use of Ingersoll Rand svnthetic compressor lubricant and 60%
continuous duty operation with the use of petroleum lubricant�� In other
words synthetic lubricant allows the compressor to pump continuously
without cycling�� Petroleum lubricant limits the compressor to a maximum
of 6 minutes of pumping time per hour�� The compressor should not cycle
more than 10 times per hour��
1��
Close the service valve��
2��
Release any remaining tank pressure by slowly opening the
manual drain valve��
��
Close the manual drain valve and apply power to the compressor��
If the pressure switch is equipped with an "ON/ AUTO-OFF" lever,
flip the switch to the "ON/AUTO" position�� If the unit is equipped
with a control panel "ON/OFF" switch, move the switch to the
"ON" position��
NORMAL START-UP
1��
Set the pressure switch lever to 'OFF"��
2��
Close the service valve��
��
Attach hose and accessory��
4��
Move the pressure switch lever to 'ON/AUTO"�� The unit will start��
5��
Allow tank pressure to build�� The motor will stop when tank pressure
reaches cut-out pressure��
6��
Open the service valve�� The unit is now ready for use��
NOTICE
When the receiver tank pressure drops below the factory pre-set
minimum, the pressure switch resets and restarts the unit��
22204945 Rev C
RELEASED 05/Apr/2018 15:16:08 GMT
OPERATION
WHEN YOU ARE FINISHED:
1��
Set the pressure switch lever to 'OFF"��
2��
Close the service valve fully��
��
Remove the air tool or accessory
4��
Slowly open the service valve to bleed air pressure down to 20 psig��
5��
Slowly open the manual drain valve at the bottom of the tank to
drain all condensate (water)��
6��
Close the drain valve and the service valve for the next use��