Table of contents
Safety ......................................................................................... 2
Service ....................................................................................... 2
Introduction ............................................................................... 3
Setup ..................................................................................... 3
Maintenance .............................................................................. 4
Troubleshooting ....................................................................... 5
Français ..................................................................................... 6
Español.................................................................................... 10
Parts List ............................................................................ 14-17
wiring Diagram ....................................................................... 18
warranty .................................................................................. 20
Introduction
This High Volume/Low Pressure (HVLP) spray system is
designed for applying coatings to surfaces that can be sprayed
faster than brushing or rolling and are too small for traditional
airless sprayers. Components of this system include a power
switch, a power cord, a filter warning light, a circuit breaker
switch, a dual filtration system, a cup holder, an air hose, and an
air outlet.
The turbine is also equipped with a tool box. It is located on the
reverse side of the turbine and can be used to store projector
sets or any other small spare parts.
Circuit
breaker
switch
Filter
warning
light
Filter
(in end of
filter can)
Power
switch
Air outlet
With this HVLP spray system, you can achieve the highest quality
professional finish possible with little or no preparation or setup
time. Please review all the information contained in this manual
before operating the system.
using an hvLP Spray System
Refer to the following information to operate and understand your
HVLP spray system.
your system may include a short air ("whip") hose. The
short hose should be connected to the longer hose or a
remote spraying system (sold separately) and NOT directly
to the turbine. See your spray gun instruction manual for
complete instructions.
© Titan Tool Inc. All rights reserved.
Cup holder
Air inlet
Filter
*Air hose not pictured
Turbine
Air hose
IMPORTaNT: Do not attach the short air whip hose directly
to the turbine, as the hose will become damaged.
Setup
Use the following procedure to set up your HVLP spray system
for operation.
1. Plug the turbine power cord into a grounded, 3-slot
receptacle.
keep the turbine at the maximum possible distance
from the spray area to safeguard against explosion
or fire that may be caused by sparking electrical
parts.
2. Prepare your spray gun for operation. Refer to your spray
gun manual for material preparation, setup, and spraying
information.
3. Attach the air hose to the air outlet on the turbine.
4. Attach the air hose to the air inlet on your spray gun.
5. Turn on the turbine and begin spraying.
Dual Filtration System
The turbine has two different air filters- one for atomizing air
and one for cooling air. The atomizing air filter is a two-stage,
fine mesh filter designed to trap particles that may damage your
finish. The atomizing air is discharged through the nozzle of the
spray gun where it atomizes the coating material. The cooling air
filter is a coarse mesh filter designed to allow the proper amount
of air flow through the turbine for cooling purposes. Cooling air
is exhausted through the cooling air discharge on the front of the
turbine.
Rear of turbine
Cooling air
intake
Filter warning System
The filter warning system on your turbine consists of a red filter
warning light on the front control panel and an air flow switch
inside the turbine. When the air flow switch does not detect the
appropriate amount of air flowing through the turbine, the filter
warning light will come on to indicate that it is time to clean or
change the filters.
NOTE: The filter warning system does not shut down the
turbine.
IMPORTaNT: clean filters regularly. clogged filters can
cause excessive heat and possibly damage the turbine.
3
Spray gun
Coupling
Whip hose
Atomizing air
discharge
Atomizing air
intake
Cooling air
discharge
English