Installation Procedure
This conversion process adjusts the flow of gas to the
burners to accommodate an LP gas fuel source.
CAUTION
TURN OFF GAS AND ELECTRICITY.
If the cooktop is installed in the counter,
1) shut off the gas valve for the gas supply line to
the cooktop.
2) remove the cooktop power cord from the
electrical outlet or turn off the breaker at the breaker
box.
3) turn all control knobs to the "Off"position.
Checklist
Each of the following steps must be completed
correctly for the appliance to function properly.
Check off each step as it is finished.
__ Step 1 - Convert the pressure regulator to use LP gas.
__ Step 2 - Remove the grates andburner caps. Remove
the Natural Gas (NG) orifices and replace them with
the LP gas orifices supplied with this kit.
__ Setp 3 - Replace the burner caps and grates
__ Step 4 - Adjust the unit valves to LP settings.
Step 1 - Convert the Pressure Regulator
Locate the pressure regulator on the bottom right end of
the cooktop.
Note:
The arrow on the back of the regulator must
point in the direction of the gas flow to the
cooktop.
.
Remove the hexagon shaped cap from the regulator
making sure not to dislodge the gasket on the cap or the
spring inside the regulator.
.
Grasp the plastic button stem (stem) firmly and pull it
forcefully from the metal cap. The stem snaps snugly into
an indent in the cap and may require a strong pull to
remove. (Hint: it may be helpful to gently "rock" the plastic
stem while pulling it from the metal cap.")
After removing the stem from the cap, rotate the stem 180°
so the button end of the stem is away from the cap and the
letters "LP" on the stem are upside down when the cap is
set flat on its head. Snap the stem back in place in this
plastic
button stem
spring
gasket
English 3