Energy Levels; Device Sensors - Silk’n Jewel H3210 Manual Del Usuario

Ocultar thumbs Ver también para Jewel H3210:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118
Button
Skin colour
sensor light
(#5)
EN

4.6 Energy levels

U
The energy level determines the intensity of the light pulse
delivered to your skin. As the energy level increases, so do
the results, as well as the risk of possible side effects and
complications (see section 5.3 Possible side effects).
U
The device has 5 levels of energy from 1 (the lowest) to 5
(the highest), represented by 5 energy level indicator lights
(#2). To change levels, short press the control button (#3).
U
To determine the right energy level for your treatment area,
refer to section 6.3 Perform a spot test.

4.7 Device sensors

The device has sensors for touch, movement, and colour.
U
Touch and movement: The device will only emit
repeated pulses when it is in firm contact with your skin,
and you keep moving it across your skin.
U
Colour: Light-based hair removal on darker skin tones may
result in adverse effects such as burns, blisters, and skin
colour changes (hyper- or hypopigmentation). The device
has a skin colour sensor (#7) that detects the colour of your
skin automatically. The skin colour sensor (#7) checks your
skin colour at the start of, and occasionally during, each
treatment.
Function / Mode
• Green blinks: skin colour is too dark
for safe use.